Direct Reconstruction Methods in Optical Tomography
نویسنده
چکیده
Optical tomography is a biomedical imaging modality that uses scattered light as a probe of structural variations in the optical properties of tissue [1]. In a typical experiment, a highly-scattering medium is illuminated by a narrow collimated beam and the light that propagates through the medium is collected by an array of detectors. In first generation systems, the sources and detectors are coupled to the medium by means of optical fibers. The number of measurements that can be obtained in this manner varies from 10 to 10 source-detector pairs. More recently, noncontact imaging systems have been introduced, wherein a scanned beam and a lens-coupled CCD camera is employed to replace the illumination and detection fiber-optics of firstgeneration systems, as shown in Fig. 1.1. Using such a noncontact method, extremely large data sets of order 10 measurements can be obtained. The inverse problem of optical tomography is to reconstruct the optical properties of a medium of interest from boundary measurements. The mathematical formulation of the corresponding forward problem is dictated primarily by spatial scale, ranging from the Maxwell equations at the microscale, to the radiative transport equation at the mesoscale, and to diffusion theory at the macroscale. The standard approach to the inverse problem is framed in terms of nonlinear optimization. It is important to note that although optimization methods are extremely flexible, they lead to iterative algorithms with very high computational cost. Direct reconstruction methods offer an alternative approach that can fill this gap. By direct reconstruction, we mean the use of inversion formulas and associated fast algorithms.
منابع مشابه
Direct-current-based image reconstruction versus direct-current included or excluded frequency-domain reconstruction in diffuse optical tomography.
We study the level of image artifacts in optical tomography associated with measurement uncertainty under three reconstruction configurations, namely, by using only direct-current (DC), DC-excluded frequency-domain, and DC-included frequency-domain data. Analytic and synthetic studies demonstrate that, at the same level of measurement uncertainty typical to optical tomography, the ratio of the ...
متن کاملAn Efficient Method for Model Reduction in Diffuse Optical Tomography
We present an efficient method for the reduction of model equations in the linearized diffuse optical tomography (DOT) problem. We first implement the maximum a posteriori (MAP) estimator and Tikhonov regularization, which are based on applying preconditioners to linear perturbation equations. For model reduction, the precondition is split into two parts: the principal components are consid...
متن کاملDifferential imaging in heterogeneous media: limitations of linearization assumptions in optical tomography
Image reconstruction and data collection in optical tomography can be achieved in a number of different ways. This paper explores the limitations of using assumptions of linearity, particularly in the case where image data is acquired before and after a change in optical properties within an object with heterogeneous optical properties. The effects of using a 2 dimensional (2D) reconstruction s...
متن کاملA Direct Linear Reconstruction Method for Spectrally Resolved 3D Bioluminescence Tomography
Spectrally-resolved BioLuminescence optical Tomography (sBLT) is used to recover images of Luciferase activity within a 3D mouse model using multi-wavelength emission data from multiple internal bioluminescence sources. The images show that the location of sources can be reconstructed accurately using a fast, direct and linear reconstruction algorithm. ©2006 Optical Society of America OCIS code...
متن کاملSiemens primus accelerator simulation using EGSnrc Monte Carlo code and gel dosimetry validation with optical computed tomography system by EGSnrc code
Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers. Monte Carlo modeling of the Siemens Primus linear accelerator in 6 MeV beams was used. Square field size of 10 × 10 cm2 produced by the jaws was compared with TLD. Head simulation of Siemens accele...
متن کامل