Monitoring oral anticoagulant treatment with the TAS near-patient test system: comparison with conventional thromboplastins.

نویسندگان

  • S Kitchen
  • F E Preston
چکیده

BACKGROUND A number of instruments have been developed for determination of prothrombin time (PT) and International Normalised Ratio (INR) at locations not limited to central laboratories. AIM To evaluate one such portable instrument, the Thrombolytic Assessment System (TAS), which can be used in a near-patient setting. METHODS Samples from 20 normal subjects and 48 patients treated with warfarin for venous thromboembolic disease were studied. The warfarin group was divided into: initiation phase (n = 10), combined warfarin and heparin (n = 10), stabilised therapy (n = 20), and over anticoagulated patients (n = 8). PTs and INRs were determined in each group using three conventional thromboplastins (Diagen Activated, Manchester Reagent, and Instrumentation Laboratory) and two TAS techniques (whole blood or plasma). An independent International Sensitivity Index (ISI) calibration of the TAS system was performed. RESULTS Calculated ISIs for the TAS were 1.028 and 0.984 for plasma and whole blood analysis, respectively, compared with manufacturer's values of 0.98 and 0.97. INR results with TAS (whole blood) were 11% less than those obtained with Diagen Activated (p < 0.01) and 16% less than those obtained with Instrumentation Laboratory (p < 0.001) when manufacturers' mean normal PT and ISI were used for TAS INRs. TAS (whole blood) results were similar to TAS plasma or Manchester Reagent results. The use of a locally determined mean normal prothrombin time (MNPT) improved agreement between TAS and the other reagents, abolishing the significant difference between INRs determined with TAS (whole blood) and Diagen Activated techniques. CONCLUSION The TAS system can be used with whole blood or plasma and produces similar INRs to those obtained with Diagen Activated or Manchester Reagent using manufacturer's ISI and a locally determined MNPT. Results were lower with TAS or Manchester Reagent compared with those obtained with Instrumentation Laboratory thromboplastin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A critical evaluation of the prothrombin time for monitoring oral anticoagulant therapy.

The Quick prothrombin time is the most common clotting test performed, principally for monitoring oral anticoagulant therapy. The International Normalized Ratio (INR) for comparing patient results from prothrombin time measurements and the International Standardized Index (ISI) for achieving greater consistency of results using different thromboplastins have made it possible to compare the resu...

متن کامل

Has the time arrived to replace the quick prothrombin time test for monitoring oral anticoagulant therapy?

The Quick (1 ) and Owren (2 ) prothrombin time (PT) tests remain the basis for monitoring anticoagulant therapy worldwide. The use of these tests is remarkable because the Quick PT preceded the discovery of the anticoagulant effect of dicoumarol in spoiled sweet clover and both tests were in use long before there was any understanding of the mechanism of the action of oral anticoagulants or whi...

متن کامل

Effect of Oral Anticoagulant Therapy on Coagulation Activity and Inflammatory Markers in Patients with Atrial Fibrillation Undergoing Ablation: A Randomized Comparison between Dabigatran and Warfarin

  Atrial fibrillation (AF) is associated with inflammatory and hypercoagulability state. Previous studies evaluated the safety and efficacy of dabigatran and warfarin in prevention of thrombothic complications. This study was intended to assess the influence of these drugs on hemostatic and inflammatory markers among patient underwent pulmonary vein ablation.   A total of 100 patients with AF w...

متن کامل

Effect of Oral Anticoagulant Therapy on Coagulation Activity and Inflammatory Markers in Patients with Atrial Fibrillation Undergoing Ablation: A Randomized Comparison between Dabigatran and Warfarin

  Atrial fibrillation (AF) is associated with inflammatory and hypercoagulability state. Previous studies evaluated the safety and efficacy of dabigatran and warfarin in prevention of thrombothic complications. This study was intended to assess the influence of these drugs on hemostatic and inflammatory markers among patient underwent pulmonary vein ablation.   A total of 100 patients with AF w...

متن کامل

Evaluation of the Antithrombotic Effects of Rivaroxaban and Apixaban Using the Total Thrombus-Formation Analysis System®: In Vitro and Ex Vivo Studies

BACKGROUND The usefulness of the Total Thrombus-Formation Analysis System® (T-TAS®) for monitoring the anticoagulant effects of non-vitamin K oral anticoagulants (NOACs) in clinical practice has been poorly addressed. METHODS NOACs (rivaroxaban and apixaban) were added to whole blood from healthy subjects in an in vitro study, and their effects on thrombus formation were evaluated by the T-TA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 50 11  شماره 

صفحات  -

تاریخ انتشار 1997