Adenosine stress high-pitch 128-slice dual-source myocardial computed tomography perfusion for imaging of reversible myocardial ischemia: comparison with magnetic resonance imaging.
نویسندگان
چکیده
BACKGROUND Coronary computed tomography angiography (CTA) enables accurate anatomic evaluation of coronary artery stenosis but lacks information about hemodynamic significance. The aim of this study was to evaluate 128-slice myocardial CT perfusion (CTP) imaging with adenosine stress using a high-pitch mode, in comparison with cardiac MRI (CMR). METHODS AND RESULTS Thirty-nine patients with intermediate to high coronary risk profile underwent adenosine stress 128-slice dual source CTP (128×0.6 mm, 0.28 seconds). Among those, 30 patients (64 ± 10 years, 6% women) also underwent adenosine stress CMR (1.5T). The 2-step CTP protocol consisted of (1) adenosine stress-CTP using a high-pitch factor (3.4) ECG-synchronized spiral mode and (2) rest-CTP/coronary-CTA using either high-pitch (heart rate <63 bpm) or prospective ECG-triggering (heart rate >63 bpm). Results were compared with CMR and with invasive angiography in 25 patients. The performance of stress-CTP for detection of myocardial perfusion defects compared with CMR was sensitivity, 96%; specificity, 88%; positive predictive value (PPV), 93%; negative predictive value (NPV), 94% (per vessel); and sensitivity, 78%; specificity, 87%; PPV, 83%; NPV, 84% (per segment). The accuracy of stress-CTP for imaging of reversible ischemia compared with CMR was sensitivity, 95%; specificity, 96%; PPV, 95%; and NPV, 96% (per vessel). In 25 patients who underwent invasive angiography, the accuracy of CTA for detection of stenosis >70% was (per segment): sensitivity, 96%; specificity, 88%; PPV, 67%; and NPV, 98.9%. The accuracy improved from 84% to 95% after adding stress CTP to CTA. Radiation exposure of the entire stress/rest CT protocol was only 2.5 mSv. CONCLUSIONS Adenosine-induced stress 128-slice dual-source high-pitch myocardial CTP allows for simultaneously assessment of reversible myocardial ischemia and coronary stenosis, with good diagnostic accuracy as compared with CMR and invasive angiography, at a very low radiation exposure.
منابع مشابه
Adenosine Stress High-pitch 128-slice Dual Source Myocardial Computed Tomography Perfusion For Imaging Of Reversible Myocardial Ischemia: Comparison with Magnetic Resonance Imaging Feuchtner et al: Myocardial Perfusion Imaging with CT
Background Coronary computed tomography angiography (CTA) enables accurate anatomic evaluation of coronary artery stenosis, however lacking information about hemodynamical significance. The aim of this study was to evaluate 128-slice myocardial CT perfusion (CTP) imaging with adenosine stress using a high-pitch mode, in comparison with cardiac magnetic resonance imaging (CMR). Methods and Resul...
متن کاملMyocardial ischemia evaluation with dual-source computed tomography: comparison with magnetic resonance imaging.
INTRODUCTION AND OBJECTIVES Computed tomography does not accurately determine which coronary lesions lead to myocardial ischemia and consequently further tests are required to evaluate ischemia induction. The aim of this study was to compare diagnostic accuracy between dual-energy computed tomography and magnetic resonance imaging in the assessment of myocardial perfusion and viability in patie...
متن کاملStress and rest dynamic myocardial perfusion imaging by evaluation of complete time-attenuation curves with dual-source CT.
OBJECTIVES This study sought to describe a protocol for myocardial perfusion imaging using dipyridamole stress, with 128-slice dual-source computed tomography (CT), and to assess the ability of CT myocardial perfusion imaging (MPI) to detect abnormal flow reserve and infarction in comparison with nuclear MPI (NMPI). BACKGROUND CT MPI has not been previously described with the 128-slice dual-s...
متن کاملComparison between left ventricular electromechanical mapping and radionuclide perfusion imaging for detection of myocardial viability.
BACKGROUND A novel 3-dimensional left ventricular (LV) mapping system uses low-intensity magnetic field energy to determine the location of sensor-tipped electrode catheters within the LV. Using this system, we sought to distinguish between infarcted, ischemic, and normal myocardium by comparing LV electromechanical mapping data with myocardial perfusion imaging studies. METHODS AND RESULTS U...
متن کاملA comparison of high-resolution and standard cardiovascular magnetic resonance myocardial perfusion imaging for the detection of myocardial ischaemia
Background First pass myocardial perfusion imaging by CMR may permit the detection of myocardial ischaemia with greater accuracy than single photon emission computed tomography (SPECT). Technical developments have led to improvements in myocardial perfusion CMR, particularly through accelerated data acquisition methods. These permit the acquisition of data at higher spatial resolution than conv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Cardiovascular imaging
دوره 4 5 شماره
صفحات -
تاریخ انتشار 2011