Changes in interface pressure and stump shape over time: preliminary results from a trans-tibial amputee subject.
نویسندگان
چکیده
Interface stresses and stump shape were measured during sessions over a two-month interval on a trans-tibial amputee subject. Results from thirteen transducer sites monitored during four sessions showed greater interface pressure changes over time at anterior sites than at lateral or posterior locations. There was a trend of decreased pressure with stump swelling and increased pressure for stump atrophy. During one session in which stump shape was monitored over a 23.1 min interval after ambulation, stump swelling was localised. Swelling tended to increase in the regions of initial enlargement, as opposed to redistributing through different areas over time. Regions of swelling were anterior lateral and posterior proximal, areas of thick underlying soft tissue. Identification of localised areas of swelling and atrophy and understanding of their effects on interface pressures could be used to improve individual socket design.
منابع مشابه
The Capability of Fiber Bragg Grating Sensors to Measure Amputees' Trans-Tibial Stump/Socket Interface Pressures
This study presents the first investigation into the capability of fiber Bragg grating (FBG) sensors to measure interface pressure between the stump and the prosthetic sockets of a trans-tibial amputee. FBG element(s) were recoated with and embedded in a thin layer of epoxy material to form a sensing pad, which was in turn embedded in a silicone polymer material to form a pressure sensor. The s...
متن کاملEngineering a trans-tibial prosthetic socket for the lower limb amputee.
INTRODUCTION This review addresses the different prosthetic socket designs for trans-tibial amputees, the biomechanics behind the designs and the current state of the field. Of particular focus is the classic patella-tendon bearing (PTB) socket and the more recent sockets manufactured using pressure casting techniques and the theory, biomechanics and clinical implications of the two designs. Me...
متن کاملEnergy expenditure of trans-tibial amputees during ambulation at self-selected pace.
The purpose of this investigation was two-fold: 1) to compare the metabolic cost (VO2), heart rate (HR), and self-selected speed of ambulation of trans-tibial amputees (TTAs) with those of non-amputee subjects; and 2) to determine whether a correlation exists between either stump length or prosthesis mass and the energy cost of ambulation at the self-selected ambulation pace of TTAs. Subjects w...
متن کاملClinical measurement of normal and shear stresses on a trans-tibial stump: characteristics of wave-form shapes during walking.
Stresses on the surface of a stump within a prosthetic socket during walking can potentially traumatize stump tissues. To gain insight into stresses and design parameters that affect them, normal and shear interface stresses were measured on three unilateral trans-tibial amputee subjects during walking trials. During stance phase repeated characteristics in wave-form shapes from different subje...
متن کاملRelationship between socket pressure and EMG of two muscles in trans-femoral stumps during gait.
The biomechanical interaction between the leg stump and the prosthetic socket is critical in achieving close-to-normal ambulation. Although many investigations have been performed to understand the biomechanics of trans-tibial sockets, few studies have measured the socket interface pressure for transfemoral amputees. Furthermore, no report has examined how the residual muscle activities in the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Prosthetics and orthotics international
دوره 24 2 شماره
صفحات -
تاریخ انتشار 2000