Multi‐isocentric 4π volumetric‐modulated arc therapy approach for head and neck cancer

نویسندگان

  • Vallinayagam Shanmuga Subramanian
  • Vellaiyan Subramani
  • Srinivas Chilukuri
  • Murugesan Kathirvel
  • Gandhi Arun
  • Shanmugam Thirumalai Swamy
  • Kala Subramanian
  • Antonella Fogliata
  • Luca Cozzi
چکیده

OBJECTIVES To explore the feasibility of multi-isocentric 4π volumetric-modulated arc therapy (MI4π-VMAT) for the complex targets of head and neck cancers. METHODS Twenty-five previously treated patients of HNC underwent re-planning to improve the dose distributions with either coplanar VMAT technique (CP-VMAT) or noncoplanar MI4π-VMAT plans. The latter, involving 3-6 noncoplanar arcs and 2-3 isocenters were re-optimized using the same priorities and objectives. Dosimetric comparison on standard metrics from dose-volume histograms was performed to appraise relative merits of the two techniques. Pretreatment quality assurance was performed with IMRT phantoms to assess deliverability and accuracy of the MI4π-VMAT plans. The gamma agreement index (GAI) analysis with criteria of 3 mm distance to agreement (DTA) and 3% dose difference (DD) was applied. RESULTS CP-VMAT and MI4π-VMAT plans achieved the same degree of coverage for all target volumes related to near-to-minimum and near-to-maximum doses. MI4π-VΜΑΤ plans resulted in an improved sparing of organs at risk. The average mean dose reduction to the parotids, larynx, oral cavity, and pharyngeal muscles were 3 Gy, 4 Gy, 5 Gy, and 4.3 Gy, respectively. The average maximum dose reduction to the brain stem, spinal cord, and oral cavity was 6.0 Gy, 3.8 Gy, and 2.4 Gy. Pretreatment QA results showed that plans can be reliably delivered with mean gamma agreement index of 97.0 ± 1.1%. CONCLUSIONS MI4π-VMAT plans allowed to decrease the dose-volume-metrics for relevant OAR and results are reliable from a dosimetric standpoint. Early clinical experience has begun and future studies will report treatment outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose Distribution Analysis of Rapid Arc and Intensity Modulated Radiotherapy Plan in Head and Neck Cancer

Introduction: Globally, intensity-modulated radiation therapy (IMRT) is considered as highly precise and accurate method of radiotherapy planning. This technique amplifies spatial dose distribution conformity by modulating the intensity of radiation beams in each sub-volume. Additionally, it can reduces the dose to surrounding critical organs and deliver the planned dose to targets with the nom...

متن کامل

Multi-institutional comparison of volumetric modulated arc therapy vs. intensity-modulated radiation therapy for head-and-neck cancer: a planning study

BACKGROUND Compared to static beam Intensity-Modulated Radiation Therapy (IMRT), the main advantage of Volumetric Modulated Arc Therapy (VMAT) is a shortened delivery time, which leads to improved patient comfort and possibly smaller intra-fraction movements. This study aims at a treatment planner-independent comparison of radiotherapy treatment planning of IMRT and VMAT for head-and-neck cance...

متن کامل

Treatment planning comparison of IMPT, VMAT and 4π radiotherapy for prostate cases

BACKGROUND Intensity-modulated proton therapy (IMPT), non-coplanar 4π intensity-modulated radiation therapy (IMRT), and volumetric-modulated arc therapy (VMAT) represent the most advanced treatment methods based on heavy ion and X-rays, respectively. Here we compare their performance for prostate cancer treatment. METHODS Ten prostate patients were planned using IMPT with robustness optimizat...

متن کامل

Potential advantages of volumetric arc therapy in head and neck cancer.

BACKGROUND Intensity-modulated radiation therapy (IMRT) uses solid compensators or multileaf collimators to modulate the intensity of radiation in each field, delivering highly conformal dose distributions. This technique allows treating volumes with concave shapes when the target is close to a critical structure. The movement of multileaf collimator under computer control can modulate the dose...

متن کامل

Evaluation of volumetric modulated arc therapy (VMAT) with Oncentra MasterPlan® for the treatment of head and neck cancer

BACKGROUND Several comparison studies have shown the capability of VMAT to achieve similar or better plan quality as IMRT, while reducing the treatment time. The experience of VMAT in a multi vendor environment is limited. We compared the plan quality and performance of VMAT to IMRT and we investigate the effects of varying various user-selectable parameters. METHODS IMRT, single arc VMAT and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017