In film cooling heat transfer analysis, one of the core concepts is to deem film cooled adiabatic wall temperature (Taw) as the driving potential for the actual heat flux over the filmcooled surface. Theoretically, the concept of treating Taw as the driving temperature potential is drawn from compressible flow theory when viscous dissipation becomes the heat source near the wall and creates higher wall temperature than in the flowing gas. But in conditions where viscous dissipation is negligible, which is common in experiments under laboratory conditions, the heat source is not from near the wall but from the main hot gas stream; therefore, the concept of treating the adiabatic wall temperature as the driving potential is subjected to examination. To help investigate the role that Taw plays, a series of computational simulations are conducted under typical film cooling conditions over a conjugate wall with internal flow cooling. The result and analysis support the validity of this concept to be used in the film cooling by showing that Taw is indeed the driving temperature potential on the hypothetical zero wall thickness condition, ie. Taw is always higher than Tw with underneath (or internal) cooling and the adiabatic film heat transfer coefficient (haf) is always positive. However, in the conjugate wall cases, Taw is not always higher than wall temperature (Tw), and therefore, Taw does not always play the role as the driving potential. Reversed heat transfer through the airfoil wall from downstream to upstream is possible, and this reversed heat flow will make Tw > Taw in the near injection hole region. Yet evidence supports that Taw can be used to correctly predict the heat flux direction and always result in a positive adiabatic heat transfer coefficient (haf). The results further suggest that two different test walls are recommended for conducting film cooling experiments: a low thermal conductivity material should be used for obtaining accurate Taw and a relative high thermal conductivity material be used for conjugate cooling experiment. Insulating a highconductivity wall will result in Taw distribution that will not provide correct heat flux or haf values near the injection hole.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Discussion about the Practice of Using a Heated Surface in Film Cooling Studies

It is found in many film-cooling experiments and computational analyses that a heated surface is employed to simulate the actual film-cooling condition with a cooling jet and a hot main flow. Considering that the dominant energy passage in turbine airfoil film cooling is always from the hot combustion gas flowing into the airfoil, employing a heated surface to simulate the actual film cooling c...

متن کامل

A Revised Equation for Heat Flux Reduction in Film Cooling Studies and Discussion of Its Applications

In film cooling experimental studies, due to the difficulty in measuring the surface heat flux variation, a Heat Flux Ratio (HFR) equation originally derived by Mick and Mayle [1], has been widely employed to calculate the surface heat flux distribution using the measured adiabatic film effectiveness and surface temperature. A close examination of the derivation process and applications of the ...

متن کامل

Irreversibility Analysis of MHD Buoyancy-Driven Variable Viscosity Liquid Film along an Inclined Heated Plate Convective Cooling

Analysis of intrinsic irreversibility and heat transfer in a buoyancy-driven changeable viscosity liquid along an incline heated wall with convective cooling taking into consideration the heated isothermal and isoflux wall is investigated. By Newton’s law of cooling, we assumed the free surface exchange heat with environment and fluid viscosity is exponentially dependent on temperature. Appropr...

متن کامل

An Innovation in Film Cooling of the Gas Turbine Blades Applying an Upstream Jet

A new design concept is introduced to control the near-wall integration between the hot-gas boundary layer and the cooling jets in order to enhance the adiabatic film cooling effectiveness of the gas turbine blades. In this new approach, another film cooling port, having a very low blowing ratio, which prevents formation of the counter-rotating vortex pare, is applied just upstream of the main ...

متن کامل

Numerical Simulation of Laminar Film Cooling in a Supersonic Boundary Layer using Modeled and Simulated Blowing

Direct numerical simulations are used to investigate the method of film cooling in a laminar flat-plate Mach-2.67 boundary layer. Air is employed as mean-flow and coolant gas and is injected into an adiabatic or isothermal boundary layer through one or two rows of staggered, discrete holes. Previous simulations were performed using a modeled blowing approach, where the mass flux and temperature...