Evaluation of bowel distention with a neutral contrast agent: some statistical concerns.

نویسنده

  • Sukru Mehmet Erturk
چکیده

Editor: I read with great interest the article by Dr Megibow and colleagues (1) in the January 2006 issue of Radiology. I have some concerns about the Materials and Methods and Results sections of this article. In the Materials and Methods section, under the subtitle “Statistical Analysis,” the authors state that the two groups included in their study were compared with respect to the mean values for each segment of the gastrointestinal tract (stomach, duodenum, jejunum, and ileum) by using the Mann-Whitney test, and they add that the combined mean scores were compared at a 95% confidence level by using the Wilcoxon signed rank test. As it is known, whereas a Mann-Whitney U test is used when ordinal data are obtained in the independent groups situation, a Wilcoxon signed rank test is used when ordinal data are obtained in the paired samples situation (2). In this case, the use of a Mann-Whitney U test seems appropriate since the two groups were composed of different patients. Nevertheless, it is not clear which test was really employed by the authors. In the Results section, under the subtitle “Qualitative Analysis,” the authors report that the mean value for distention in the ileum was significantly higher in group 1 than group 2. However, they give a P value of .140 that by definition does not indicate significance at the 5% -error level. This point needs to be clarified. Finally, since the qualitative image analysis included two independent readers and their combined mean scores were used for statistical comparisons, it might have been meaningful to evaluate the interobserver agreement with statistics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of bowel distention and bowel wall appearance by using neutral oral contrast agent for multi-detector row CT.

PURPOSE To prospectively evaluate the performance of an orally administered 0.1% barium suspension, Volumen, as a bowel-marking agent for multi-detector row computed tomography (CT). MATERIALS AND METHODS This HIPAA-compliant study was approved by the Institutional Review Board and conformed to the institutional standards for research funded by a commercial sponsor. A total of 60 patients (33...

متن کامل

بررسی یافته های رادیولوژیک در نوزادان مبتلا به هیرشپرونگ در مرکز آموزشی درمانی بوعلی سینای ساری طی سال های 87-86

Background and purpose: Diagnosis of Hirschprung's disease is one of the most important problems of pediatric surgeons and leaving it without treatment has its own complications. Early diagnosis in younger age with special attention to clinical and radiological findings can reduce these complications. The aim of this study was to compare the findings of plain abdominal radiography and contras...

متن کامل

Synthesis and evaluation of chitosan manganese-ferrite nanoparticles as MRI contrast agent

Magnetic nanoparticles are the good choice for using in MRI as the contrast agent. Iron oxide particles such as magnetite (Fe3O4) or its oxidized form maghemite (γ-Fe2O3) are the most commonly employed in biomedical applications. In this study, we synthesized and optimized the preparation of chitosan manganese-ferrite nanoparticles (CMn-Fe nps) and evaluated its ability for the mice macrophage ...

متن کامل

Synthesis and evaluation of chitosan manganese-ferrite nanoparticles as MRI contrast agent

Magnetic nanoparticles are the good choice for using in MRI as the contrast agent. Iron oxide particles such as magnetite (Fe3O4) or its oxidized form maghemite (γ-Fe2O3) are the most commonly employed in biomedical applications. In this study, we synthesized and optimized the preparation of chitosan manganese-ferrite nanoparticles (CMn-Fe nps) and evaluated its ability for the mice macrophage ...

متن کامل

Comparison of Water, Mannitol and Positive Oral Contrast for Evaluation of Bowel By Computed Tomography

IntrOductIOn Imaging of the bowel has been a challenge to the radiologists. Each imaging modality has its own merits and demerits. The small bowel is always a challenging area for surgeon and gastroenterologist because of its long length and patients with bowel pathology present with vague symptoms. Barium investigation is less sensitive [1,2]. Capsule endoscopy gives a lot of information about...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 241 3  شماره 

صفحات  -

تاریخ انتشار 2006