Single Event Upsets in Implantable Cardioverter Defibrillators

نویسندگان

  • P. D. Bradley
  • E. Normand
چکیده

Single event upsets (SEU) have been observed in implantable cardiac defibrillators. The incidence of SEUs is well modeled by upset rate calculations attributable to the secondary cosmic ray neutron flux. The effect of recent interpretations of the shape of the heavy ion cross-section curve on neutron burst generation rate calculations is discussed. The model correlates well with clinical experience and is consistent with the expected geographical variation of the secondary cosmic ray neutron flux. The observed SER was 9.3 × 10 upsets/bit-hr from 22 upsets collected over a total of 284672 device days. This is the first clinical data set obtained indicating the effects of cosmic radiation on implantable devices. Importantly, it may be used to predict the susceptibility of future implantable device designs to cosmic radiation. The significance of cosmic radiation effects relative to other radiation sources applicable to implantable devices is discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inappropriate Shocks in Patients with ICDs: Single Chamber versus Dual Chamber

BACKGROUND Despite the technological evolution of the implantable defibrillator, one of the questions that remains is the possible benefit of the dual chamber versus single chamber implantable cardioverter defibrillator (ICD) in reducing inappropriate shocks. OBJECTIVE To evaluate which type of device provides fewer inappropriate shocks (dual chamber versus single chamber) in patients with im...

متن کامل

Implantable cardioverter defibrillator during laser transurethral resection of the prostate

  Implantable cardioverter defibrillators have been instrumental in the health and safety of patients who are at increased risk of sudden death by ventricular tachycardia or fibrillation. Consensus on the perioperative management of cardiovascular implantable electronic devices has suggested that certain surgical interventions (including transurethral resection of the prostate) may interfere wi...

متن کامل

Implantable Cardioverter Defibrillators Proportion of patients needing an implantable cardioverter defibrillator on the basis of current guidelines: impact on healthcare resources in Italy and the USA. Data from the ALPHA study registry

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CLINICAL RESEARCH Implantable Cardi...

متن کامل

Healthcare Utilization and Expenditures Associated With Appropriate and Inappropriate Implantable Defibrillator Shocks.

BACKGROUND In patients with implantable cardioverter-defibrillators, healthcare utilization (HCU) and expenditures related to shocks have not been quantified. METHODS AND RESULTS We performed a retrospective cohort study of patients with implantable cardioverter-defibrillators identified from commercial and Medicare supplemental claims databases linked to adjudicated shock events from remote ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998