The Influence of Pelvic Ramus Fracture on the Stability of Fixed Pelvic Complex Fracture
نویسندگان
چکیده
This study aims to evaluate the biomechanical mechanism of pelvic ring injury for the stability of pelvis using the finite element (FE) method. Complex pelvic fracture (i.e., anterior column with posterior hemitransverse lesion) combined with pelvic ramus fracture was used to evaluate the biomechanics stability of the pelvis. Three FE fracture models (i.e., Dynamic Anterior Plate-Screw System for Quadrilateral Area (DAPSQ) for complex pelvic fracture with intact pubic ramus, DAPSQ for complex pelvic fracture with pubic ramus fracture, and DAPSQ for complex pelvic fracture with fixed pubic ramus fracture) were established to explore the biomechanics stability of the pelvis. The pubic ramus fracture leads to an unsymmetrical situation and an unstable situation of the pelvis. The fixed pubic ramus fracture did well in reducing the stress levels of the pelvic bone and fixation system, as well as displacement difference in the pubic symphysis, and it could change the unstable situation back to a certain extent. The pelvic ring integrity was the prerequisite of the pelvic stability and should be in a stable condition when the complex fracture is treated.
منابع مشابه
Are occult fractures of the hip and pelvic ring mutually exclusive?
We have evaluated retrospectively the relationship of bony injuries seen on 106 consecutive MR scans in elderly patients of a mean age of 81.4 years (67 to 101) who were unable to bear weight after a low-energy injury. There were no visible fractures on plain radiographs of the hip but eight patients (7.5%) had fractures of the pubic ramus. In 43 patients (40.5%) MRI revealed a fracture of the ...
متن کاملThe functional outcome of surgically treated unstable pelvic ring fractures by open reduction, internal fixation
Abstract Background: Unstable Pelvic fracture, a result of high energy antero-posterior compression injury, has been managed based on internal fixation and open reduction. The mode of fixation in Unstable Pelvic fracture has, however, been a subject of controversy and some authors have proposed a need to address the issue of partial breach of the pelvic ring elements in these injuries. This st...
متن کاملObturator Artery Injury Resulting in Massive Hemorrhage From a Low-Energy Pubic Ramus Fracture.
Pelvic ring fractures are common in the elderly population and are usually a result of low-energy trauma, such as falls from standing. In most cases, low-energy pelvic ring injuries can be treated with appropriate analgesia and early mobilization. Arterial injury resulting in hemodynamic instability from a low-energy pelvic ring injury is rare but, given the poor compliance of vessels in the el...
متن کاملAre two retrograde 3.5 mm screws superior to one 7.3 mm screw for anterior pelvic ring fixation in bones with low bone mineral density?
OBJECTIVES Osteosynthesis of anterior pubic ramus fractures using one large-diameter screw can be challenging in terms of both surgical procedure and fixation stability. Small-fragment screws have the advantage of following the pelvic cortex and being more flexible.The aim of the present study was to biomechanically compare retrograde intramedullary fixation of the superior pubic ramus using ei...
متن کاملUrinary bladder herniation into pubic ramus fracture.
A young adult male was admitted after suffering polytrauma due to road traffic accident. Emergency radiography showed pelvic fracture. Computed tomography (CT) scan was performed which revealed presence of comminuted displaced fracture of left superior pubic ramus. Fracture line was extending till pubic symphysis but no symphyseal diastasis was noted. In addition, a part of urinary bladder was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2015 شماره
صفحات -
تاریخ انتشار 2015