Calibration of a Thomson scattering diagnostic for fluctuation measurements.
نویسندگان
چکیده
Detailed calibrations of the Madison Symmetric Torus polychromator Thomson scattering system have been made suitable for electron temperature fluctuation measurements. All calibrations have taken place focusing on accuracy, ease of use and repeatability, and in situ measurements wherever possible. Novel calibration processes have been made possible with an insertable integrating sphere (ISIS), using an avalanche photodiode (APD) as a reference detector and optical parametric oscillator (OPO). Discussed are a novel in situ spatial calibration with the use of the ISIS, the use of an APD as a reference detector to streamline the APD calibration process, a standard dc spectral calibration, and in situ pulsed spectral calibration made possible with a combination of an OPO as a light source, the ISIS, and an APD used as a reference detector. In addition a relative quantum efficiency curve for the APDs is obtained to aid in uncertainty analysis.
منابع مشابه
Improvements to the calibration of the MST Thomson scattering diagnostic.
Calibration of the Madison Symmetric Torus Thomson scattering system has been refined to improve temperature fluctuation measurements. Multiple avalanche photodiodes have been directly calibrated for use as reference detectors during calibration, improving accuracy and ease of use. From the absolute calibration we calculate corrections to the gain for variation in detector operating temperature...
متن کاملCorrection of the spectral calibration of the Joint European Torus core light detecting and ranging Thomson scattering diagnostic using ray tracing.
This work isolated the cause of the observed discrepancy between the electron temperature (T(e)) measurements before and after the JET Core LIDAR Thomson Scattering (TS) diagnostic was upgraded. In the upgrade process, stray light filters positioned just before the detectors were removed from the system. Modelling showed that the shift imposed on the stray light filters transmission functions d...
متن کاملIdentification and mitigation of stray laser light in the Thomson scattering system on the Madison Symmetric Torus (MST).
The Thomson scattering diagnostic on the Madison Symmetric Torus (MST) records excessive levels of stray Nd:YAG laser light. Stray light saturates the 1064 nm spectral channel in all polychromators, which prevents absolute electron density measurements via Rayleigh scattering calibration. Furthermore, stray light contaminates adjacent spectral channels for r/a ≥ 0.75, which renders the diagnost...
متن کاملA Self-calibration Method for the Edge Thomson Scattering Diagnostic in ITER
Calibration of spectral transmissivity of the collection and transmission optics is one of the most crucial issues for the Thomson scattering diagnostic system. Radioactivation of the vacuum vessel in ITER makes it difficult to calibrate spectral transmissivity in areas near the vacuum vessel. By using an additional calibration laser whose wavelength differs from those of the diagnostic laser a...
متن کاملUpgrades to improve the usability, reliability, and spectral range of the MST Thomson scattering diagnostic.
The Thomson scattering diagnostic on MST records both equilibrium and fluctuating electron temperature with a range capability of 10 eV-5 keV. Standard operation with two modified commercial Nd:YAG lasers allows measurements at rates of 1 kHz-25 kHz. Several subsystems of the diagnostic are being improved. The power supplies for the avalanche photodiode detectors (APDs) that record the scattere...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 79 10 شماره
صفحات -
تاریخ انتشار 2008