Quantification of left ventricular volumes and function in anesthetized beagles using real-time three-dimensional echocardiography: 4D-TomTec™ analysis versus 4D-AutLVQ™ analysis in comparison with cardiac magnetic resonance imaging

نویسندگان

  • Judith Eskofier
  • Patrick Wefstaedt
  • Martin Beyerbach
  • Ingo Nolte
  • Stephan O. Hungerbühler
چکیده

BACKROUND Real-time three-dimensional echocardiography (RT3DE) enables accurate volume determination of the left ventricle (LV), since measurements in foreshortened depicted views are avertable. Different analyzing programs are available for this RT3DE. The commonly used semi-automatic software 4D-AutLVQ™ showed underestimation of LV volumes in comparison with CMRI in healthy anesthetized dogs (Am J Vet Res 74(9):1223-1230, 2013). TomTec 4D LV-Function™ is an offline analysis program for morphological and functional analyses of the left ventricle by using manual measurement optimization, showing excellent agreement with CMRI in human medicine (Echocardiography 27(10):1263-1273, 2010; Eur J Echocardiogr 11(4):359-368, 2010; Echocardiography 24(9):967-974, 2007). The aim of the present study was to compare these different RT3DE analyzing software programs to test the possibility of one performing better than the other by assessing accuracy and reproducibility in comparison with the reference method cardiac magnetic resonance imaging (CMRI) by determining the left ventricular end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF). RT3DE and CMRI were performed during anesthesia in 10 healthy beagles. The analyzing programs 4D-AutLVQ™ (based on semi-automated border detection) and TomTec 4D LV-Function™ (primary manual tracking with semi-automated border detection) were used for RT3DE volume analysis of the left ventricle. Left ventricular EDV, ESV, SV and EF were measured and compared to those measured by the reference method CMRI. Repeated measurements were performed to determine inter- and intra-observer variability. RESULTS Both, 4D-AutLVQ™ and 4D-TomTec™ showed small but significant underestimation for EDV and ESV with quite good correlation (r = 0.34-0.69) in comparison with CMRI, without significant difference between each of them. Ejection fraction (EF) measured by 4D-TomTec™ showed no significant differences compared to CMRI (p = 0.12), while 4D-AutLVQ™ significantly underestimated LV-EF (p = 0.03). Analyzing time was shorter using 4D-AutLVQ™ compared to 4D-TomTec™. The inter-observer variability was higher using 4D-TomTec™ than with 4D-AutLVQ™, whereas both methods present excellent intra-observer variability. CONCLUSION 4D-TomTec™ and 4D-AutLVQ™ are feasible RT3DE analyzing programs, allowing accurate volume quantification of the left ventricle, albeit with significant underestimation of ventricular volumes in comparison with the gold standard CMRI. 4D-AutLVQ™ is performed faster with less inter-observer variability than 4D-TomTec™. Therefore, 4D-AutLVQ™ is the more practicable measurement method when comparing the different analyzing programs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Semi-automated quantification of left ventricular volumes and ejection fraction by real-time three-dimensional echocardiography

BACKGROUND Recent studies have shown that real-time three-dimensional (3D) echocardiography (RT3DE) gives more accurate and reproducible left ventricular (LV) volume and ejection fraction (EF) measurements than traditional two-dimensional methods. A new semi-automated tool (4DLVQ) for volume measurements in RT3DE has been developed. We sought to evaluate the accuracy and repeatability of this m...

متن کامل

Mechanical resynchronisation in biventricular pacing illustrated by real time transthoracic three dimensional echocardiography.

A 74 year old man with dilated cardiomyopathy and right bundle branch block underwent implantation of a biventricular pacemaker for treatment of severe heart failure. When reviewed six weeks later his New York Heart Association functional class had improved from III to I. Using the Sonos 7500 Live 3D system, a real time transthoracic three dimensional echocardiogram was performed in the presenc...

متن کامل

Quantification of LV Volumes with 4D Real-Time Echocardiography

This paper presents a new 4D (3D + Time) expansion of echocardiographic volumes on complex exponential wavelet-like basis functions called Brushlets [1]. Brushlet functions offer good localization in time and frequency and decompose a signal into distinct patterns of oriented textures, invariant to intensity and contrast range. Automatic left ventricle (LV) endocardial border detection is carri...

متن کامل

New generation 3-dimensional echocardiography for left ventricular volumetric and functional measurements: comparison with cardiac magnetic resonance.

AIMS Non-invasive assessment of left ventricular (LV) structure and function is important in the evaluation of cardiac patients. This study was designed to test the accuracy and reproducibility of new generation 3-dimensional echocardiography (3DE) in measuring volumetric and functional LV indices as compared with current "gold standard" of non-invasive cardiac imaging, cardiac magnetic resonan...

متن کامل

Atlas-based analysis of 4D flow CMR: Automated vessel segmentation and flow quantification

BACKGROUND Flow volume quantification in the great thoracic vessels is used in the assessment of several cardiovascular diseases. Clinically, it is often based on semi-automatic segmentation of a vessel throughout the cardiac cycle in 2D cine phase-contrast Cardiovascular Magnetic Resonance (CMR) images. Three-dimensional (3D), time-resolved phase-contrast CMR with three-directional velocity en...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2015