Determination of inadvertent atrial capture during para-Hisian pacing.

نویسندگان

  • Manoj Obeyesekere
  • Peter Leong-Sit
  • Allan Skanes
  • Andrew Krahn
  • Raymond Yee
  • Lorne J Gula
  • Matthew Bennett
  • George J Klein
چکیده

BACKGROUND Inadvertent capture of the atrium will lead to spurious results during para-Hisian pacing. We sought to establish whether the stimulation-to-atrial electrogram interval at the proximal coronary sinus (stim-PCS) or high right atrium (stim-HRA) could signal inadvertent atrial capture. METHODS AND RESULTS Para-Hisian pacing with and without intentional atrial capture was performed in 31 patients. Stim-HRA and stim-PCS intervals were measured with atrial capture, His plus para-Hisian ventricular (H+V) capture, and para-Hisian ventricular (V) capture alone. The mean stim-HRA interval was significantly shorter with atrial capture (66 ± 18 ms) than with H+V (121 ± 27 ms, P < 0.001) or V capture alone (174 ± 38 ms, P < 0.001). The mean stim-PCS interval was significantly shorter with atrial capture (51 ± 16 ms) than with H+V (92 ± 22 ms, P<0.001) or V capture alone (146 ± 33 ms, P < 0.001). A stim-PCS < 60 ms (stim-HRA < 70 ms) was observed only with atrial capture. A stim-PCS >90 ms (stim-HRA >100 ms) was observed only in the absence of atrial capture. A stim-HRA of < 85 ms was highly specific and stim-PCS of < 85 ms highly sensitive at identifying atrial capture. Stim-HRA intervals of 75 to 97 ms and stim-PCS intervals of 65 to 88 ms were observed with either atrial, His, or para-Hisian ventricular capture without atrial capture. In this overlap zone, all patients demonstrated a stim-PCS or stim-HRA interval prolongation of at least 20 ms when the catheter was advanced to avoid deliberate atrial pacing. The QRS morphology was of limited value in distinguishing atrial capture due to concurrent ventricular or H+V capture, as observed in 20 of 31 (65%) patients. CONCLUSIONS Stim-PCS and stim-HRA intervals can be used to monitor for inadvertent atrial capture during para-Hisian pacing. A stim-PCS < 60 ms (or stim-HRA < 70 ms) and stim-PCS > 90 ms (or stim-HRA > 100 ms) were observed only with and without atrial capture, respectively, but there was significant overlap between these values. Deliberate atrial capture and loss of capture reliably identifies atrial capture regardless of intervals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Para-Hisian pacing. A new method for differentiating retrograde conduction over an accessory AV pathway from conduction over the AV node.

BACKGROUND Differentiation between ventriculoatrial (VA) conduction over an accessory AV pathway (AP) and the AV node (AVN) may be difficult, especially in patients with a septal AP. METHODS AND RESULTS A new pacing method, para-Hisian pacing, was tested in 149 patients with AP and 53 patients without AP who had AV nodal reentrant tachycardia (AVNRT). Ventricular pacing was performed adjacent...

متن کامل

Paradoxical Response During Para-hisian Pacing: What is the Mechanism?

A 64 year old lady underwent electrophysiologic study for recurrent episodes of palpitation and documented narrow complex tachycardia. 12 lead ECG showed normal sinus rhythm and no evidence of preexcitation. At baseline, the cycle length, AH and HV intervals were 776, 52 and 46 ms respectively. Para-Hisian pacing was done at baseline and the response is shown in figure 1. The pacing output duri...

متن کامل

His bundle capture proximal to the site of bundle branch block: A novel pitfall of the para-Hisian pacing maneuver

Paced QRS morphology should be assessed to differentiate between complete loss of His bundle capture and loss of distal His bundle capture alone. This might be enough in patients with proximal right bundle branch block; however, in patients with proximal left bundle branch block, QRS morphology might be similar with loss of His bundle capture and with proximal His bundle capture. Introduction T...

متن کامل

Entrainment from the para-Hisian region for differentiating atrioventricular node reentrant tachycardia from orthodromic atrioventricular reentrant tachycardia.

AIMS The difference between the stimulus-atrial and ventriculo-atrial intervals (SA-VA) and between the post-pacing interval and the tachycardia cycle length (PPI-TCL) during entrainment from the right ventricular apex distinguishes atrioventricular node reentrant (AVNRT) from orthodromic atrioventricular reentrant tachycardia (AVRT). We hypothesized that these features still apply when entrain...

متن کامل

Accurate evaluation of para-Hisian pacing in a patient with fasciculoventricular bypass.

A 20-year-old man with palpitations was examined for ventricular pre-excitation. Atrial extra-stimulation produced AH prolongation without changes in the pre-excitation degree, suggesting fasciculoventricular bypass. Para-Hisian pacing with different stimuli strengths induced various beats, including His-bundle pacing. QRS morphologies of these different responses were similar because the dista...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 4 4  شماره 

صفحات  -

تاریخ انتشار 2011