Extracranial carotid artery in patients with transient global amnesia: evaluation by real-time B-mode ultrasonography with duplex Doppler flow.

نویسندگان

  • D Feuer
  • J Weinberger
چکیده

Patients with transient global amnesia are often categorized as having cerebrovascular disease. Noninvasive carotid artery testing was performed in 56 patients with transient global amnesia to determine if they had the same incidence of extracranial atherosclerotic vascular disease as patients with focal cerebral transient ischemic attacks. Only 3 of 56 patients had hemodynamic obstruction of flow at the carotid artery bifurcation, and 41 of 56 had no evidence of any atherosclerotic disease. Other risk factors for cerebrovascular disease were present in 24 of 56 patients, but only 1 had a prior cerebrovascular event. The pathophysiology of transient global amnesia appears to differ from the pathophysiology of classical transient ischemic attacks in that there is no clear relation between transient global amnesia and the presence of extracranial atherosclerotic cerebrovascular disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارزیابی و بررسی نتایج حاصل از داپلر فراصوتی در مقایسه با آنژیوگرافی تفریقی دیجیتال در تشخیص تنگ شدگیهای شریان کاروتید داخلی

Introduction: Digital Subtraction Angiography (DSA) is the standard method for detection of carotid artery stenosis. This technique has high radiation dose. With the progress of imaging techniques, noninvasive or minimally invasive methods like the CT angiography, MR angiography and ultrasonography with Doppler or Duplex mode were applicable. This study aimed to evaluate and assesse the results...

متن کامل

Ultrasonic duplex scanning for disease of the carotid artery.

The duplex ultrasonic scanner combines real-time B-mode imaging with a single-gate, variable-range pulsed Doppler. The detection and categorization of the severity of carotid artery atherosclerosis is achieved by performing spectral analysis of the pulsed Doppler velocity signal obtained from vessels of interest. Using this technique, 750 patients with suspected extracranial carotid artery dise...

متن کامل

Influence of acetazolamide and CO2 on extracranial flow volume and intracranial blood flow velocity.

BACKGROUND AND PURPOSE The vasomotor response can be tested by means of transcranial Doppler sonography. If a constant vessel diameter is assumed, the flow velocity changes will reflect blood flow volume changes. This hypothesis is difficult to verify. Simultaneous assessment of intracranial flow velocity and extracranial flow volume changes may solve this problem. METHODS We tested vasomotor...

متن کامل

Echocontrast-enhanced ultrasound of extracranial internal carotid artery high-grade stenosis and occlusion.

BACKGROUND AND PURPOSE Proper assessment of extracranial internal carotid artery high-grade stenosis and occlusion by extracranial color-coded duplex sonography (ECCD) is occasionally made difficult by shadowing, an unfavorable insonation angle, low flow velocity or volume, or a deep insonation depth. In these cases, echocontrast could be helpful to quantify the degree of stenosis and to diagno...

متن کامل

Power M-Mode Doppler and single-gate spectral analysis using a 2-MHz pulsed-wave Doppler transducer to directly detect cervical internal carotid artery stenosis: use of the continuity principle: report of a novel technique.

BACKGROUND AND PURPOSE We hypothesized that direct cervical investigation with Power M-Mode Doppler (PMD) combined with single-gate Doppler spectral analysis (SGDSA) using a 2-MHz pulsed-wave Doppler transducer would show reasonable accuracy parameters when compared with standard color-coded carotid duplex ultrasound (CDU). METHODS We prospectively screened for cervical internal carotid arter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 18 5  شماره 

صفحات  -

تاریخ انتشار 1987