Biomechanical and histological evaluation of a hydroxyapatite-coated titanium femoral stem fixed with an intramedullary morsellized bone grafting technique: an animal experiment on goats.

نویسندگان

  • B W Schreurs
  • R Huiskes
  • P Buma
  • T J Slooff
چکیده

To reconstruct femoral intramedullary bone-stock loss in revision surgery of failed total hip arthro-plasties, morsellized trabecular bone grafts can be used. In 14 goats a noncemented hydroxyapatite-coated titanium stem was fixed within a circumferential construction of bone allografts. After 6 or 12 wk, four goats were used for mechanical tests and three for histology. The stability of the stems relative to the bone was determined in a loading experiment with Roentgenstereo-Photogrammatic Analysis (RSA). Owing to two loosenings and two fractures, only one 6-wk specimen and three 12-wk specimens were available for mechanical testing. The prostheses were very stable at 12 wk. The most important movements were axial rotation (maximal 0.17 degrees at 800 N) and subsidence (maximal 0.036 mm at 800 N). After unloading, there was 40-60% elastic recovery. Histological examination showed revascularization and remodelling of the graft in all the specimens investigated. At the graft site, bone apposition and bone resorption had resulted in a mixture of graft and new bone. Bone incorporation was mainly seen in the proximal areas. Graft lysis was evident in the midshaft region and at distal levels around the prostheses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bone Tissue Response to Plasma Sprayed Hydroxyapatite Coatings: An In Vivo Study on Rabbit Femoral Condyles

     In this study, hydroxyapatite was coated on titanium substrates by plasma spraying process. A well-known porous and lamellar microstructure was found in the lateral a...

متن کامل

Histological and biomechanical analysis of bone and interface reactions around hydroxyapatite-coated intramedullary implants of different stiffness: a pilot study on the goat.

We hypothesized that reduced stem stiffness of orthopaedic implants contributes to a high risk of loosening, since interface stresses and relative motions may exceed a tolerable range. To study this hypothesis, three types of load-bearing implant with different stiffnesses were inserted into the tibia of the goat. Histological analysis was performed of bone repair after insertion of the implant...

متن کامل

Morsellized bone grafting compensates for femoral bone loss in revision total knee arthroplasty. An experimental study.

This study was undertaken to examine the contribution of uncontained morsellized bone graft to the structural properties of a femoral reconstruction in total knee arthroplasty and to serve as a basis for an in vivo animal study. Ten human distal femora with a standard unicondylar uncontained medial bone defect were prepared to fit a femoral component of a cruciate sacrificing TKA. A cyclic axia...

متن کامل

Assessment of retention force and bone apposition in two differently coated femoral stems after 6 months of loading in a goat model

BACKGROUND Since the introduction of uncemented hip implants, there has been a search for the best surface coating to enhance bone apposition in order to improve retention. The surface coating of the different stems varies between products. The aim was to assess the retention force and bone adaption in two differently coated stems in a weight-bearing goat model. MATERIALS AND METHODS Hydroxya...

متن کامل

Autogenous Osteochondral Transplantation Mosaicplasty (An Animal Study on Sheep)

Background: Autogenous osteochondral grafting of articular defect in weight-bearing surface of large joints has proven to be a proper biomechanical and physiological solution for localized full-thickness defects.Objective: To study the gross and histopathological results of mosaicplasty in an animal model (sheep’s medial femoral condyle), evaluating the factors of defect and graft size, assessi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomaterials

دوره 17 12  شماره 

صفحات  -

تاریخ انتشار 1996