Long-term improvement in left ventricular strain after successful catheter ablation for atrial fibrillation in patients with preserved left ventricular systolic function.

نویسندگان

  • Laurens F Tops
  • Dennis W Den Uijl
  • Victoria Delgado
  • Nina Ajmone Marsan
  • Katja Zeppenfeld
  • Eduard Holman
  • Ernst E van der Wall
  • Martin J Schalij
  • Jeroen J Bax
چکیده

BACKGROUND The effect of successful catheter ablation on left ventricular (LV) strain in patients with preserved LV systolic function is unknown. The aim of the present study was to assess the long-term effects of catheter ablation for atrial fibrillation (AF) on LV strain and strain rate in patients with preserved LV ejection fraction. METHODS AND RESULTS In 78 patients undergoing catheter ablation for AF, speckle tracking strain imaging was performed to assess LV strain in 3 directions (radial, circumferential, and longitudinal) at baseline and after 12-month follow-up. The study population was divided into 2 groups, according to the maintenance of sinus rhythm (SR) during follow-up. After 13.8+/-4.7 months of follow-up, 54 patients (69%) were in SR (SR group), whereas 24 patients (31%) had recurrence of AF (AF group). No significant changes in LV ejection fraction from baseline to follow-up were noted (60+/-7% versus 59+/-7%, P=NS). Circumferential strain improved significantly in the SR group (-18.3+/-3.2% versus -20.4+/-3.8%, P<0.001), whereas it remained unchanged in the AF group (-18.9+/-3.5% versus -17.9+/-3.1%, P=NS). In the SR group, significant improvements in LV longitudinal strain and strain rate were noted, whereas in the AF group, LV longitudinal strain and strain rate deteriorated significantly at long-term follow-up. CONCLUSIONS After successful catheter ablation, LV circumferential and longitudinal strain and strain rate improve significantly in patients who maintain SR. In contrast, a decrease in LV longitudinal strain and strain rate is observed in patients with recurrence of AF.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Left Atrial Diastolic Dysfunction following Catheter Ablation of Atrial Fibrillation.

Radiofrequency catheter ablation (RFCA)-induced thermal injury may cause and/or worsen left atrial (LA) diastolic dysfunction leading to pulmonary hypertension and heart failure in patients with atrial fibrillation (AF), the incidence of which is probably more common than is generally realized. Biplane 2-dimensional echocardiography coupled with tissue Doppler (velocity) imaging and Doppler-der...

متن کامل

Catheter ablation of atrial fibrillation in patients with left ventricular systolic dysfunction: a systematic review and meta-analysis.

BACKGROUND Catheter ablation of atrial fibrillation (AFCA) is an established therapeutic option for rhythm control in symptomatic patients. Its efficacy and safety among patients with left ventricular systolic dysfunction is based on small populations, and data concerning long-term outcome are limited. We performed this meta-analysis to assess safety and long-term outcome of AFCA in patients wi...

متن کامل

Prospective study of left ventricular function after radiofrequency ablation of atrioventricular junction in patients with atrial fibrillation.

BACKGROUND In patients with drug resistant incessant supraventricular tachycardia, radiofrequency induced ablation of the atrioventricular junction and pacemaker implantation have hitherto been considered a treatment of last resort. OBJECTIVE To assess the short and long term effects of ablation of the atrioventricular junction on systolic and diastolic left ventricular function in patients w...

متن کامل

Assessment of Atrial Fibrillation and Vulnerability in Patients with Wolff-Parkinson-White Syndrome Using Two-Dimensional Speckle Tracking Echocardiography

PURPOSE The aim was to assess atrial fibrillation (AF) and vulnerability in Wolff-Parkinson-White (WPW) syndrome patients using two-dimensional speckle tracking echocardiography (2D-STE). METHODS All patients were examined via transthoracic echocardiography and 2D-STE in order to assess atrial function 7 days before and 10 days after RF catheter ablation. A postoperative 3-month follow-up was...

متن کامل

Success of ablation for atrial fibrillation in isolated left ventricular diastolic dysfunction: a comparison to systolic dysfunction and normal ventricular function.

BACKGROUND The efficacy of radiofrequency ablation for atrial fibrillation (AF) in patients with left ventricular (LV) systolic dysfunction and isolated diastolic dysfunction is uncertain. METHODS AND RESULTS A prospective cohort of patients with normal and abnormal LV function underwent ablation for antiarrhythmic drug (AAD)-refractory AF. Three groups were compared: 111 patients with systol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 2 3  شماره 

صفحات  -

تاریخ انتشار 2009