Smart syringe pumps for drug infusion during dental intravenous sedation

نویسندگان

  • Kwang-Suk Seo
  • Kiyoung Lee
چکیده

Dentists often sedate patients in order to reduce their dental phobia and stress during dental treatment. Sedatives are administered through various routes such as oral, inhalation, and intravenous routes. Intravenous administration has the advantage of rapid onset of action, predictable duration of action, and easy titration. Typically, midazolam, propofol or dexmedetomidine are used as intravenous sedatives. Administration of these sedatives via infusion by using a syringe pump is more effective and successful than infusing them as a bolus. However, during intravenous infusion of sedatives or opioids using a syringe pump, fatal accidents may occur due to the clinician's carelessness. To prevent such risks, smart syringe pumps have been introduced clinically. They allow clinicians to perform effective sedation by using a computer to control the dose of the drug being infused. To ensure patient safety, various alarm features along with a drug library, which provides drug information and prevents excessive infusion by limiting the dose, have been added to smart pumps. In addition, programmed infusion systems and target-controlled infusion systems have also been developed to enable effective administration of sedatives. Patient-controlled infusion, which allows a patient to control his/her level of sedation through self-infusion, has also been developed. Safer and more successful sedation may be achieved by fully utilizing these new features of the smart pump.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy evaluation of syringe pump developed for continuous drug infusion

BACKGROUND In dental intravenous sedation, continuous intravenous infusion of a low-dose drug requires an infusion pump such as a syringe pump. To develop a new syringe pump for clinical use, the functions of the pump must meet certain international standards. Various safety and efficacy tests must be performed on the syringe pump, as stipulated by these standards, and an approval must be recei...

متن کامل

Standard drug concentrations and smart-pump technology reduce continuous-medication-infusion errors in pediatric patients.

OBJECTIVE To determine if combining standard drug concentrations with "smart-pump" technology reduces reported medication-infusion errors. DESIGN Preintervention and postintervention comparison of reported medication errors related to infusion therapies during the calendar years 2002 and 2003. SETTING A 242-bed university-affiliated tertiary pediatric hospital. INTERVENTION Change in cont...

متن کامل

A controlled trial of smart infusion pumps to improve medication safety in critically ill patients.

OBJECTIVE Intravenous medications are vital during inpatient management. Errors associated with the administration of medications through intravenous infusion pumps to critically ill patients can result in adverse drug events. We sought to assess the impact of smart pumps with integrated decision support software on the incidence and nature of medication errors and adverse drug events. DESIGN...

متن کامل

Clinical Informatics: Recursive Concurrence Intravenous Medication Administration Systems Protocols for Addressing the Potential Problem of Recessive Lethal Autonomy in Smart Infusion Systems

Smart Infusion Pumps are vital tools for use in administering a broad range of parenteral/intravenous medications. Safe and effective use of smart infusion pumps depends upon their integration with Pump Servers, Computerized Physician Order Entry Systems, Pharmacy Information Systems, DERS/MERS – Dose/Medication Error Reduction Systems( and the digital Drug Libraries that they use), eMARS – ele...

متن کامل

Dexmedetomidine intravenous sedation using a patient-controlled sedation infusion pump: a case report

Dental treatment under sedation requires various sedation depths depending on the invasiveness of the procedure and patient drug sensitivity. Inappropriate sedation depth may cause patient discomfort or endangerment. For these reasons, patient-controlled sedation (PCS) pumps are commonly used. Patients are able to control the sedation depths themselves by pushing the demand button after the pra...