1. Rotational mobility of a widely used rotating platform total knee replacement. Iowa Orthop J, 2001. 21: p. 90. 2. Multi-contact-surface finite element model of a widely used rotating platform total knee. Polyethylene wear in meniscal knee replacement. A one to nine-year retrieval analysis of the Oxford knee.Unicompartmental "Lotus" knee prosthesis. Analysis of the results of a series of 142 cases (of which 56 had a follow-up of more than 5 years)]. The Oxford knee replacement. A review from an independent centre. Dislocation/subluxation of meniscal bearing elements after New Jersey low-contact stress total knee arthroplasty. Delayed failure of meniscal bearing elements in total knee arthroplasty. Wear in retrieved condylar knee arthroplasties. A comparison of wear in different designs of 280 retrieved condylar knee prostheses.
منابع مشابه
Midterm Results of Cementless and Cemented Unicondylar Knee Arthroplasty with Mobile Meniscal Bearing: A Prospective Cohort Study
Background Cemented unicompartmental knee arthroplasty (UKA) yields good clinical outcome but common revision reasons are loosening and pain. Cementless UKA may reduce the revision rate. Objective The current study was designed to assess clinical and radiographic outcome of cemented and cementless UKA, using bone quality as determined by the Bone Hardness Test (BHT) as selection criterion for...
متن کاملUnicompartmental knee arthroplasty. 2- to 12-year results in a community hospital.
We report the outcome of 135 knees with anteromedial osteoarthritis in which the Oxford meniscal-bearing unicompartmental arthroplasty was inserted in a district general hospital by a single surgeon. All the knees had an intact anterior cruciate ligament, a correctable varus deformity and the lateral compartment was uninvolved or had only minor osteoarthritis. The mean follow-up was 5.82 years ...
متن کاملDoes mobile-bearing knee arthroplasty motion change with activity?
BACKGROUND The purpose of this study was to evaluate the effect of mobile-bearing implant design and activity on knee arthroplasty kinematics during three activities of daily living. METHODS In vivo kinematics were analyzed using 3D model registration from fluoroscopic images of non-weightbearing knee flexion-extension, weight-bearing squatting and stair activities in 20 knees in 10 patients ...
متن کاملRe: Comparison of mobile-bearing and fixed-bearing total knee arthroplasty: a prospective randomized study.
The purpose of this prospective randomized study was to compare the postoperative recovery and early results of 2 groups of patients undergoing total knee arthroplasty: 107 patients received an established fixed-bearing posterior-stabilized prosthesis (Legacy Posterior Stabilized [LPS]), and 103 patients the meniscal-bearing prosthesis (Meniscal Bearing Knee [MBK]). Surgical procedures were the...
متن کاملLong-term outcome of low contact stress total knee arthroplasty with different mobile bearing designs.
PURPOSE to evaluate the differences in clinical outcome and survivorship of three different mobile bearings for total knee arthroplasty. METHODS a retrospective study was conducted in 60 patients (53 females, 7 males, mean age: 68 years and 5 months) each submitted to total knee replacement using one of the three different mobile bearings of the LCS system (Depuy Johnson & Johnson, Warsaw, IN...