3D free-breathing cardiac cine imaging with respiratory and cardiac self-gating and 3D motion correction
نویسندگان
چکیده
INTRODUCTION Free-breathing cardiac cine imaging with respiratory and cardiac self-gating provides flexibility and convenience for patient scans. Here we propose a 3D radial cardiac cine imaging technique that improves upon self-gating by adding 3D respiratory motion correction. The 3D respiratory motion signals are derived from multiple projections through the data used for image reconstruction at each time point. Cardiac self-gating is also achieved based on derived cardiac motion signals. MATERIALS AND METHODS 3D cine imaging samples k-space with a stack of multi-echo radial acquisitions (radial projections filling in kx-ky plane and Cartesian encoding along kz) [1]. Slice encodes at a given angle are acquired sequentially. The angle of successive projections are incremented π/r = 111.2 (golden ratio r=1.618). Each scanned projection angles is unique, and this interleaving profile allows robust flexible time-resolved reconstruction [2]. The radial acquisitions at one angle along all slice encodes are 2D Fourier transformed to provide a xy-z profile every nzTR (Fig.1 upper left corner), where nz is the number of slice encodes. Summing up the xy-z profile along xy or z gives two image projections at each time point. These two image projections through time (xy-t and z-t) contain all 3 dimensions of motion within the FOV. Multiple adjacent projections at distinct angles (xy-t) are used to derive 2D image center of mass (COM) at x and y axes [3]. The COM along z of z-t profile is bandpass filtered to derive cardiac motion and respiratory motion along z, which are used for cardiac and respiratory selfgating [4]. The derived 3D respiratory motions are used for motion correction, by applying phase correction at each data point [5]. All coil data are combined for generating the xy-z profile. Sets of 20 consecutive projections incrementing by one projection (sliding window) through time are used for calculating the COM along x-y plane. The respiratory motion along z was used for respiratory self-gating. For the respiratory motions along three axes, 3D relative displacements were calculated and used for motion correction. Cardiac cine images are generated without sharing data among phases. Cardiac imaging was acquired at 1.5T (GE EXCITE 14.0 with maximum gradient amplitude 33 mT/m, slew-rate 120 T/m/s) with an 8-channel cardiac coil. Self-gating 3D cine imaging was performed on seven subjects in shortaxis views. Imaging parameters were: BW = ±125 kHz, FOV = 32-34 cm, reconstructed image size = 256x256, TR = 4.4 ms, nz=10, slice thickness = 10 mm. The reconstructed images have a temporal resolution of 44 ms. Acquisition time was about 3.5-5 min. RESULTS AND DISCUSSION Fig.3 shows results from a volunteer; all images are cardiac self-gated. The results without gating or motion correction (Fig.3a) show noticeable blurring of the myocardial borders as well as the papillary muscles. The respiratory self-gated results that use 50% data provide sharper borders and papillary muscles (Fig.3b) but contain residual artifacts that diminish with motion correction (Fig.3c). The 3D COMs of the data with motion correction were also derived for comparisons. For the case shown in Fig.3, the biggest displacement was 6 pixels without motion correction and was reduced to 2 pixels after 3D motion correction. This approach to deriving gating signals in three dimensions has proven to be robust. It can be combined with motion correction to improve image quality while reducing scan time. We observed that the calculated COMs along x and y axes were within reasonable ranges, while the COMs along z were suffering from low spatial resolution along the slice encoding direction. CONCLUSIONS We propose a respiratory and cardiac self-gating with 3D respiratory motion correction technique for free-breathing cardiac cine imaging. Preliminary results show improvement in image quality and reliability of self-gating signals.
منابع مشابه
Respiratory and cardiac self-gated free-breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisition.
A respiratory and cardiac self-gated free-breathing three-dimensional cine steady-state free precession imaging method using multiecho hybrid radial sampling is presented. Cartesian mapping of the k-space center along the slice encoding direction provides intensity-weighted position information, from which both respiratory and cardiac motions are derived. With in plan radial sampling acquired a...
متن کاملWhole-heart cine MRI using real-time respiratory self-gating.
Two-dimensional (2D) breath-hold cine MRI is used to assess cardiac anatomy and function. However, this technique requires cooperation from the patient, and in some cases the scan planning is complicated. Isotropic nonangulated three-dimensional (3D) cardiac MR can overcome some of these problems because it requires minimal planning and can be reformatted in any plane. However, current methods,...
متن کاملSelf-Gated Free-Breathing 3D Coronary CINE Imaging with Simultaneous Water and Fat Visualization
The aim of this study was to develop a novel technique for acquiring 3-dimensional (3D) coronary CINE magnetic resonance images with both water and fat visualization during free breathing and without external respiratory or cardiac gating. The implemented multi-echo hybrid 3D radial balanced Steady-State Free Precession (SSFP) sequence has an efficient data acquisition and is robust against mot...
متن کاملNonlinear profile order for 3D hybrid radial acquisition applied to self-gated free-breathing cardiac cine MRI
Background Self-gated free-breathing 3D cardiac cine MRI has been widely introduced, which provides similar image quality and functional measurements as breath-hold technique [1-3]. In self-gated free-breathing cardiac cine MRI, respiratory and cardiac motions are unpredictable during the acquisition especially in retrospective reconstruction. Therefore, nonuniform k-space distribution is a maj...
متن کاملThree-dimensional Whole-Heart Cine MRI using Prospective Self-Gating for Compensation of Cardiac and Respiratory Motion
Introduction: Two-dimensional (2D) breath-hold and ECG-triggered cine MRI is frequently used to assess cardiac function. However this technique requires cooperation from the patient, and the MR acquisition has to be synchronized with the cardiac cycle using ECG. To control respiratory motion, the subject has to perform breath-holds or the position of the diaphragm has to be tracked using a resp...