Biological Dosimetry of Co-60 Gamma Irradiation.

نویسندگان

  • A Top
  • M Coşkun
  • T Orta
چکیده

Development of radiation technology has resulted in increasing numbers of people working with it. Therefore it has increasingly been important to monitor the radiation in order to ensure public safety. Physical dosimetry plays an important role in monitoring. But a need arise for biological dosimetry where physical dosimetry is absent or its presence is insufficient. In this study Co-60 gamma radiation dose-response curves for chromosome aberrations were determined for use as controls in biological dosimetry. Peripheral blood that were taken from healthy individuals not working with radiation were irradiated at different radiation doses. The relationship between unstable chromosome aberrations in metaphaseblocked cells and radiation dose were drawn by using the linear-quadratic (LQ) formula. The absorbed radiation doses of the test group consisting of five people that had been working with Co-60 teletherapy machines were estimated using the LQ parameters of control dose-response curves in the Qdr method. Estimated radiation doses were below the permissible radiation dose-limits for four workers, but one worker's estimated dose was higher than these limits.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thyroids Dose Evaluation and Calculation of Backscatter Factors for Co-60 Irradiations

The aim of the study is evaluation of absorbed doses for thyroids by using neck phantoms. For this purpose, it was arranged the irradiation set with different phantoms. Three different materials were used for phantom materials as, water, paraffin and wood. The phantoms were three different dimensions for simulation of different ages and human race for each material. Co-60 gamma source was used ...

متن کامل

Effect of concentration of QDs Cadmium Sulfide in Study of Optical Properties under Gamma Irradiation in Order to use in dosimetry

In this work, for the first time, effect of gamma irradiation on the optical properties of CdS (quantum dots) QDs in various concentrations was studied. The aqueous CdS QDs were synthesized in a facile and fast method by using domestic microwave oven.  Three concentration of QDs; 20, 2, 0.4 mg/cc after different administrated dose of gamma irradiation (0-20 kGy) were studied. The results showed...

متن کامل

Comparison between Amperometric and Chemiluminescence methods in detection and dosimetry of cobalt-60 gamma ray emission

Background: Hydrogen peroxide (H2O2), produced by gamma ray irradiation to watery solution, was used as an analytical parameter for dosimetry of cobalt-60 (60Co) radiation. Materials and Methods: Detection of the produced H2O2 was carried out using two methods: an amperometric biosensor fabricated by immobilization of anthraquinone 2-carboxylic acid modified horseradish peroxidase on glassy car...

متن کامل

Development of methemoglobin-based biological dosimetry in gamma–irradiated mice

Background: A new biological dosimeter based on methemoglobin level was developed in this study. Materials and Methods: Methemoglobin level in erythrocytes from mice subjected to &gamma rays from a 60Co source was detected using the methemoglobin kit. The dose range was from 0.5 to 8 Gy and the dose rate was 0.5 Gy/min. Results: The results demonstrate that methemoglobin level increases with in...

متن کامل

Relative biological effectiveness of 31 MeV electrons, 60-Co gamma-rays and 200 KVp x-rays measured by the regression rate of splenic weight in mice.

The relative biological effectiveness of 31 MeV electrons and 6°Co gamma-rays for 200 KVp X-rays as standard was determined. As indicator, the regression rate of the splenic weight of the mouse 120 hours after whole body irradiation was adopted. When 200 KVp X-rays were chosen as standard, the relative biological effectiveness of 31 MeV electrons was 0.64 at 50% splenic regression rate and 0.72...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Turkish journal of haematology : official journal of Turkish Society of Haematology

دوره 17 4  شماره 

صفحات  -

تاریخ انتشار 2000