Quality of life in the antiarrhythmics versus implantable defibrillators trial: impact of therapy and influence of adverse symptoms and defibrillator shocks.

نویسندگان

  • Eleanor B Schron
  • Derek V Exner
  • Qing Yao
  • Louise S Jenkins
  • Jonathan S Steinberg
  • James R Cook
  • Steven P Kutalek
  • Peter L Friedman
  • Rosemary S Bubien
  • Richard L Page
  • Judy Powell
چکیده

BACKGROUND Implantable cardioverter defibrillator (ICD) use reduces mortality in patients with serious ventricular arrhythmias compared with antiarrhythmic drug (AAD) use. However, the relative impact of these therapies on self-perceived quality of life (QoL) is unknown. METHODS AND RESULTS Three self-administered instruments were used to measure generic and disease-specific QoL in Antiarrhythmics Versus Implantable Defibrillators trial participants. Generalized linear models were used to assess the relationships between self-perceived QoL and treatment (AAD versus ICD) and adverse symptoms and ICD shocks. To minimize the impact of missing data, only patients surviving 1 year were included in the primary analyses. Baseline characteristics among QoL participants (n=905) and nonparticipants (n=111) were similar, but participants who survived 1 year (n=800) were healthier at baseline than nonsurvivors (n=105). Of the 800 patients in the primary analysis, characteristics of those randomized to AAD (n=384) versus ICD (n=416) were similar. Overall, ICD and AAD use were associated with similar alterations in QoL. The development of sporadic shocks and adverse symptoms were each associated with reduced physical functioning and mental well-being and increased concerns among ICD recipients, whereas development of adverse symptoms was associated with reduced physical functioning and increased concerns among AAD recipients. CONCLUSIONS ICD and AAD therapy are associated with similar alterations in self-perceived QoL over 1-year follow-up. Adverse symptoms were associated with reduced self-perceived QoL in both groups, and sporadic shocks were associated with reduced QoL in ICD recipients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of implantable cardioverter defibrillator therapy in the Antiarrhythmics Versus Implantable Defibrillators (AVID) Trial.

INTRODUCTION The implantable cardioverter defibrillator (ICD) is commonly used to treat patients with documented sustained ventricular tachycardia (VT) or ventricular fibrillation (VF). Arrhythmia recurrence rates in these patients are high, but which patients will receive a therapy and the forms of arrhythmia recurrence (VT or VF) are poorly understood. METHODS AND RESULTS The therapy delive...

متن کامل

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

"Stable" ventricular tachycardia is not a benign rhythm : insights from the antiarrhythmics versus implantable defibrillators (AVID) registry.

BACKGROUND Sustained ventricular tachycardia (VT) can be unstable, can be associated with serious symptoms, or can be stable and relatively free of symptoms. Patients with unstable VT are at high risk for sudden death and are best treated with an implantable defibrillator. The prognosis of patients with stable VT is controversial, and it is unknown whether implantable cardioverter-defibrillator...

متن کامل

Lipid-lowering therapy for prevention of ventricular tachyarrhythmias.

In this issue of the Journal, Mitchell et al. (1) report that lipid-lowering therapy (LLT) was associated with a 36% relative risk reduction (RRR) in all-cause mortality in patients with ischemic heart disease (IHD) enrolled in the Antiarrhythmics Versus Implantable Defibrillator (AVID) trial. This rivals the benefit observed for implantable cardioverter defibrillators (ICDs) over amiodarone th...

متن کامل

Arrhythmia Management Devices

1576 Implantable cardioverter defibrillators (ICDs) save lives in patients at risk for sudden death attributable to ventricular arrhythmias, pacemakers (PMs) have been improving symptoms in patients with bradyarrhythmias for decades, and, more recently, cardiac resynchronization devices have improved mortality, morbidity, and quality of life for patients with heart failure. However, these devic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 105 5  شماره 

صفحات  -

تاریخ انتشار 2002