Arterio-venous fistula buttonhole cannulation technique: a retrospective analysis of infectious complications
نویسندگان
چکیده
BACKGROUND There are two main methods of accessing arterio-venous fistulas (AVFs); the 'buttonhole' and the 'rope-ladder' cannulation technique. Several small studies have hypothesized that the buttonhole technique is associated with increased rates of fistula-associated infection. This study addresses this hypothesis. METHODS A retrospective review of all patients attending a large outpatient haemodialysis clinic was performed. Data were collected on the method of cannulation, infection rates, implicated microorganisms, complications of infection and time on haemodialysis. RESULTS A total of 127 patients had received haemodialysis via an AVF: 53 via the rope-ladder technique and 74 via the buttonhole technique. Nine episodes of clinically significant bacteraemia were recorded in the buttonhole group. This equated to a rate of 0.073 bacteraemia events per 1000 AVF days. There were no episodes of bacteraemia in the rope-ladder group. Eight infections were due to methicillin-sensitive Staphylococcus aureus (MSSA); one was due to Staphylococcus epidermidis. Three patients with MSSA bacteraemia subsequently developed infective endocarditis. Five patients who developed bacteraemia events had been undergoing home haemodialysis. CONCLUSIONS This study highlights the infectious complications associated with buttonhole cannulation techniques. All organisms isolated in our cohort were known skin colonizers. The reason for the increased rates of infection is unclear. Given this high rate of often life-threatening infection, we recommend regular audit of infection rates. We currently do not recommend this technique to our patients receiving haemodialysis.
منابع مشابه
Cannulating in haemodialysis: rope-ladder or buttonhole technique?
BACKGROUND The standard technique for fistula cannulation, the rope-ladder technique, is problematic for patients with short fistula lengths and for patients in whom the fistula is difficult to cannulate. The buttonhole technique, cannulation of exactly the same site, offers the advantage of an easy cannulation procedure. However, it can be used only in native fistulas and cannulation is prefer...
متن کاملFrequent Hemodialysis Fistula Infectious Complications
BACKGROUND Few studies have examined if infectious arteriovenous access complications vary with the cannulation technique and whether this is modified by dialysis frequency. We compared the infection rate between fistulas cannulated using buttonhole versus stepladder techniques for patients treated with short daily (SDH) or nocturnal hemodialysis at home (NHD). We also compared patients receivi...
متن کاملButtonhole needling of haemodialysis arteriovenous fistulae results in less complications and interventions compared to the rope-ladder technique.
BACKGROUND The rope-ladder puncture technique, with cannulation along the whole length of the vessel traject, has been very common in haemodialysis patients with autogenous arterio-venous fistula (AVF). Today's dialysis population with AVF may exhibit difficult cannulation, because of a short vein length or a complicated cannulation route. An alternative needling possibility is the buttonhole (...
متن کاملSharp versus Blunt Dialysis Needle Use with Buttonhole Method: Open Randomised Trial.
BACKGROUND Current protocols recommend the use of a blunt needle to access the arteriovenous fistula via a buttonhole. This study aims to demonstrate whether a sharp needle can be used at the same buttonhole site without causing complications. GOAL To measure and compare fistula cannulation failures between the use of blunt and sharp needles. PLAN: Open-crossover randomised controlled trial. ...
متن کاملFormation of Abnormal Fistula on Arteriovenous Fistula in a Patient with Buttonhole Cannulation: A Case Report
Buttonhole cannulation has been suggested as a technique that may lead to a reduction in many complications when compared with other techniques such as rope-ladder cannulation. Despite all above, some complications still continue, which may lead to a dysfunction of the arteriovenous fistula (AVF) and inadequate dialysis, having an impact on the quality of life of the patients or eventually maki...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 5 شماره
صفحات -
تاریخ انتشار 2012