Clumped isotope measurements of small carbonate samples using a high-efficiency dual-reservoir technique.

نویسندگان

  • Sierra V Petersen
  • Daniel P Schrag
چکیده

RATIONALE The measurement of multiply substituted isotopologues of CO2 derived from carbonate has allowed the reconstruction of paleotemperatures from a single phase (CaCO3 ), circumventing uncertainty inherent in other isotopic paleothermometers. Traditional analytical techniques require relatively large amounts of carbonate (3-8 mg per replicate), which limits the applicability of the clumped isotope proxy to certain geological materials such as marine microfossils, commonly used for paleoclimate reconstructions. METHODS Clumped isotope ratio measurements of small samples were made on a new, high-efficiency, dual-reservoir sample-preparation inlet system attached to a Thermo-Finnigan MAT 253 mass spectrometer. Sample gas produced on the inlet is introduced from a 10 mL reservoir directly into the source via a capillary. Reference gas fills an identical 10 mL reservoir installed between the reference bellows and the capillary. The gas pressures in the two reservoirs are initially balanced, and are allowed to decrease together over the run. RESULTS Carbonate samples from 1 mg to 2.6 mg produced Δ47 values equivalent to those from the traditional two-bellows method with identical single-sample precision (1 SE = 0.005-0.015‰) and external standard error (SE = 0.006-0.015‰, n = 4-6). The size of sample needed to achieve good precision is controlled by the sensitivity of the mass spectrometer and the size of the fixed reservoirs and adjacent U-trap installed on our inlet. CONCLUSIONS The high-precision clumped isotope measurements of small aliquots of carbonate obtained in this method allows for the application of this proxy to a wider range of geological sample materials, such as marine microfossils, that until now have been nearly impossible to analyze given sample size limitation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Carbonate clumped isotope thermometry of deep-sea corals and implications for vital effects

Here we calibrate the carbonate clumped isotope thermometer in modern deep-sea corals. We examined 11 specimens of three species of deep-sea corals and one species of a surface coral spanning a total range in growth temperature of 2–25 C. External standard errors for individual measurements ranged from 0.005& to 0.011& (average: 0.0074&) which corresponds to 1–2 C. External standard errors for ...

متن کامل

Carbonate clumped isotope constraints on Silurian ocean temperature and seawater Î ́18O

Much of what we know about the history of Earth’s climate derives from the chemistry of carbonate minerals in the sedimentary record. The oxygen isotopic compositions (dO) of calcitic marine fossils and cements have been widely used as a proxy for past seawater temperatures, but application of this proxy to deep geologic time is complicated by diagenetic alteration and uncertainties in the dO o...

متن کامل

How small can we go? First results of a Thermo Scientific 253- Plus with a Kiel IV device for carbonate clumped isotopes

One of the main factors still limiting the application of carbonate clumped isotope thermometry to many fields of research is the relatively large amount of sample necessary for accurate measurements. In systems using a common acid bath preparation system, the most commonly used sample digestion methodology, a single analysis requires 5 to 10 mg of sample (e.g. Passey et al., 2010). Considering...

متن کامل

DIAGENESIS AND RESERVOIR QUALITY EVOLUTION OF SHELF-MARGIN SANDSTONES IN PEARL RIVER MOUTH BASIN, SOUTH CHINA SEA

A study of the diagenetic evolution of sandstones from Panyu low-uplift in the Pearl River Mouth Basin was carried out to unravel the controls on shelf margin sandstone reservoir quality. The reservoir rocks, Oligocene volcanic clastic sandstones of the Zhuhai Formation, have a burial depth of 2765 to 3440 m. 70 samples were studied using the granulometric analyses, X-ray diffraction (XRD) anal...

متن کامل

Clumped isotope analysis of carbonates: comparison of two different acid digestion techniques.

RATIONALE The kinetic nature of the phosphoric acid digestion reaction enables clumped isotope analysis of carbonates using gas source isotope ratio mass spectrometry (IRMS). In most laboratories acid digestions are performed at 25°C in sealed vessels or at 90°C in a common acid bath. Here we show that different Δ47 results are obtained depending on the digestion technique employed. METHODS S...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Rapid communications in mass spectrometry : RCM

دوره 28 21  شماره 

صفحات  -

تاریخ انتشار 2014