We propose a novel on-chip enucleation of an oocyte with zona pellucida by using a combination of untethered microrobots. To achieve enucleation within the closed space of a microfluidic chip, two microrobots, a microknife and a microgripper were integrated into the microfluidic chip. These microrobots were actuated by an external magnetic force produced by permanent magnets placed on the robotic stage. The tip of the microknife was designed by considering the biological geometric feature of an oocyte, i.e. the oocyte has a polar body in maturation stage II. Moreover, the microknife was fabricated by using grayscale lithography, which allows fabrication of three-dimensional microstructures. The microgripper has a gripping function that is independent of the driving mechanism. On-chip enucleation was demonstrated, and the enucleated oocytes are spherical, indicating that the cell membrane of the oocytes remained intact. To confirm successful enucleation using this method, we investigated the viability of oocytes after enucleation. The results show that the production rate, i.e. the ratio between the number of oocytes that reach the blastocyst stage and the number of bovine oocytes after nucleus transfer, is 100%. The technique will contribute to complex cell manipulation such as cell surgery in lab-on-a-chip devices.
منابع مشابه
On-chip enucleation of an oocyte by untethered microrobots
We propose a novel on-chip enucleation of an oocyte with zona pellucida by using a combination of untethered microrobots. To achieve enucleation within the closed space of a microfluidic chip, two microrobots, a microknife and a microgripper were integrated into the microfluidic chip. These microrobots were actuated by an external magnetic force produced by permanent magnets placed on the robot...
متن کاملEnucleation of Oocyte by On-chip robot driven by magnet with gripping mechanism
We developed a highly-functional untethered on-chip robot for cell handling and micro-knife made by Si to cut zona pellucida of oocyte. The on-chip robot has a gripping mechanism which can grasp a cell or micro-object with sufficient power. The position and handling force of the robot are controlled independently by the magnetic force. The permanent magnets and electrical magnet are assembled t...
متن کاملOocyte Enucleation Phase in Mouse Cloning
Mouse oocytes were placed in Hepes-T6 containing 7.5 μg/ml cytochalasin B and 5μg/ml Hoechst prior to enucleation, and enucleation was performed on oocytes using the manipulator. The oocyte held in place by gentle suction of a holding pipette (oocyte diameter approx.70 μm). The metaphase spindle (arrow) is aspirated into an enucleation pipette (1).
متن کاملManipulation of Oocytes by Magnetically Driven Microrobot on a Chip
This thesis presents on-chip various manipulations of oocyte, in order to improve the controllability of a single cell in the biotechnology, this thesis introduces four different approaches for a single oocyte manipulation. It includes microbeads loading for potential usage of oocytes loading, oocyte enucleation in high-speed with cutting accuracy control, single oocytes dispensing system, and ...
متن کاملP-83: Cloned Sheep Blastocysts Derived from Oocytes Enucleated Manually Using A Pulled Pasteur Pipette
Background: The potential applications of a simplified method of somatic cell nuclear transfer (SCNT) that is improved in both efficiency and throughput is considerable. Technically, a major step of SCNT is to produce large pools of enucleated oocytes (cytoplasts) efficiently, a process that requires considerable micromanipulation skill and expensive equipment. Here, we have devel oped an efficient...