The response of atrial stretch receptors to increases in heart rate in dogs.

نویسندگان

  • I H Zucker
  • J P Gilmore
چکیده

The discharge characteristics of type B left atrial receptors were analyzed during alterations in heart rate. Recordings were made from single-fiber preparations of the left cervical vagus of pentobarbital-anesthetized, open-chest dogs. The heart was paced following a sinoatrial crush at frequencies ranging from 60 to 240 beats/min. Left atrial transmural pressure was varied at each heart rate by the intravenous infusion of warm isotonic NaCl. As heart rate was increased there was a progressive decrease in the level of peak "v" wave left atrial pressure. Concomitantly with the decrease in left atrial pressure, the number of spikes per cardiac cycle decreased as did the maximal instantaneous frequency of discharge. A significant positive relationship could be demonstrated with either the discharge per minute [(spikes per cycle) X heart rate] or discharge per cycle vs. the peak "v" wave of the left atrial pressure, regardless of heart rate. The number of impulses that entered the central nervous system per unit of time remained relatively constant at heart rates between 90 and 240/min. It is concluded from these data that the reflex effects which have been attributed in the past to atrial stretch receptor stimulation during clinical episodes of atrial tachyarrhythmias may be better correlated with some aspect of receptor discharge other than frequency or the number of discharges per cycle.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impaired atrial receptor responses in dogs with heart failure due to tricuspid insufficiency and pulmonary artery stenosis.

In a study of the effects of heart failure on the responses of cardiac receptors, ten dogs were subjected to tricuspid avulsion and pulmonary artery stenosis. One case of spontaneous heart failure was included in the series, and the electrical spike responses of atrial receptors to progressive changes in atrial stretch induced by infusion and hemorrhage were contrasted with those in normal cont...

متن کامل

The mechanism of adaptation of left atrial stretch receptors in dogs with chronic congestive heart failure.

Chronic congestive heart failure (CHF) was induced in dogs by the construction of an aorto-caval fistula below the level of the renal arteries. Aorto-caval fistula dogs showed signs of CHF which included ascites, hind limb edema, and pulmonary congestion. Ventricular catheterization indicated a significantly higher left ventricular end diastolic pressure and lower maximum velocity of left ventr...

متن کامل

Cardiovascular sensory receptors and their regulatory mechanisms.

The role of cardiovascular receptors in the neural regulation of circulatory system is now well established. Atrial type B receptors located in the two atria and veno-atrial junctions, which are stimulated by atrial filling are believed to play an important role in the regulation of body fluid volume and heart rate. Heart rate is influenced also by other sensory receptors e.g. arterial barorece...

متن کامل

Small changes in left atrial pressure and plasma antidiuretic hormone titers in dogs.

JOHNSON, J* ALAN, WARD MT* MOORE, AND WILLIAM: E. SEGAR. Small changes in left atrial pressure and plasma antz’diuretic hormone titers in dogs. Am. J. Physiol. 217(l): 210-214. 1969.-Acute studies were conducted on 16 pentobarbital-anesthetized dogs to determine the effect of small increases in left atria1 pressure (LAP) 0x1 plasma ADH levels. The LAP was increased by inflating a balloon insert...

متن کامل

Cardiovascular reflexes from stretch of pulmonary vein-atrial junctions in the dog.

The reflex cardiovascular response to stretch of left pulmonary vein-atrial junctions was studied in anesthetized dogs in which both aortic nerves were cut and the carotid sinuses were isolated vascularly. After thoracotomy, the root of the left lung was tied and a small Silastic balloon (1.5-cm long), attached to a nylon catheter, was inserted into each of the three left pulmonary veins and ti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 38 1  شماره 

صفحات  -

تاریخ انتشار 1976