Factors associated with vascular complications in patients undergoing balloon-expandable transfemoral transcatheter aortic valve replacement via open versus percutaneous approaches.

نویسندگان

  • Mitul B Kadakia
  • Howard C Herrmann
  • Nimesh D Desai
  • Zachary Fox
  • Jeffrey Ogbara
  • Saif Anwaruddin
  • Dinesh Jagasia
  • Joseph E Bavaria
  • Wilson Y Szeto
  • Prashanth Vallabhajosyula
  • Robert Li
  • Rohan Menon
  • Dale M Kobrin
  • Jay Giri
چکیده

BACKGROUND Vascular complications after transfemoral transcatheter aortic valve replacement are common and associated with significant morbidity and mortality. Little is known about the effect of access approach on vascular complications. METHODS AND RESULTS Between 2007 and 2013, 331 patients underwent transfemoral transcatheter aortic valve replacement via open surgical (OS) or fully percutaneous (PC) approaches. Patient data and clinical outcomes were collected. Valve Academic Research Consortium-defined vascular complications were noted. Multivariable analysis with propensity matching was performed, and vascular complications, mortality, and length of stay were assessed. One hundred twenty patients were treated with the OS approach and 211 patients via the PC approach. There were fewer major vascular complications (11% versus 20%; P=0.03) and shorter length of stay (7.5 versus 9.9 days; P=0.003) in the PC group when compared with those in the OS group. In multivariable analysis, vascular complications were more likely in women (odds ratio, 2.2; P=0.02) and with increasing differences between sheath outer diameter and minimal artery diameter (overall vascular complications: odds ratio, 1.4; P=0.02 and major vascular complications: odds ratio, 2.0; P<0.001). Propensity-matched analysis demonstrated no difference in vascular complications between the OS and the PC groups (22% versus 19%; P=0.73) but significantly reduced length of stay in the PC group (7.9 versus 10.0 days; P=0.04). CONCLUSIONS Transfemoral transcatheter aortic valve replacement performed via the PC route is associated with similar risk of vascular complications and significantly lower postprocedural length of stay than the OS route. The degree of sheath oversizing with respect to iliofemoral minimal artery diameter and female sex are associated with vascular complications regardless of access approach.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of balloon-expandable vs self-expandable valves in patients undergoing transcatheter aortic valve replacement: the CHOICE randomized clinical trial.

IMPORTANCE Transcatheter aortic valve replacement (TAVR) is an effective treatment option for high-risk patients with severe aortic stenosis. Different from surgery, transcatheter deployment of valves requires either a balloon-expandable or self-expandable system. A randomized comparison of these 2 systems has not been performed. OBJECTIVE To determine whether the balloon-expandable device is...

متن کامل

1-Year Outcomes After Transcatheter Aortic Valve Replacement With Balloon-Expandable Versus Self-Expandable Valves: Results From the CHOICE Randomized Clinical Trial.

BACKGROUND The use of a balloon-expandable transcatheter heart valve previously resulted in a greater rate of device success compared with a self-expandable transcatheter heart valve. OBJECTIVES The aim of this study was to evaluate clinical and echocardiographic outcome data at longer term follow-up. METHODS The investigator-initiated trial randomized 241 high-risk patients with symptomati...

متن کامل

Surgical cutdown versus percutaneous access in transfemoral transcatheter aortic valve implantation: Insights from the Brazilian TAVI registry.

OBJECTIVE To compare the 1-year outcomes of complete percutaneous approach versus surgical vascular approach for transfemoral transcatheter aortic valve implantation (TAVI), among "real-world" patients from the multi-center Brazilian TAVI registry. BACKGROUND Vascular access still remains a major challenge for TAVI via transfemoral approach. Vascular access through complete percutaneous appro...

متن کامل

Procedural Results and Clinical Outcomes of Transcatheter Aortic Valve Implantation in Switzerland: An Observational Cohort Study of Sapien 3 Versus Sapien XT Transcatheter Heart Valves.

BACKGROUND New generation transcatheter heart valves (THV) may improve clinical outcomes of transcatheter aortic valve implantation. METHODS AND RESULTS In a nationwide, prospective, multicenter cohort study (Swiss Transcatheter Aortic Valve Implantation Registry, NCT01368250), outcomes of consecutive transfemoral transcatheter aortic valve implantation patients treated with the Sapien 3 THV ...

متن کامل

Image-Guided Transcatheter Aortic Valve Implantation Assistance System

Transcatheter aortic valve implantation (TAVI) is a recently developed surgical technique to treat symptomatic aortic valve stenosis in elderly and high-risk patients (Eltchaninoff et al., 2008; Ferrari & von Segesser, 2010). Compared to the standard aortic valve replacement surgery, the TAVI limits the surgical access to either a small minithoracotomy (transapical TAVI) or femoral approach (tr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 7 4  شماره 

صفحات  -

تاریخ انتشار 2014