چکیده

In nine conscious, chronically instrumented dogs, ultrasonic dimension transducers measured left ventricular anterior-posterior and septal-free wall minor axis and major axis diameters. Matched micromanometers measured right and left ventricular transmural and transeptal pressures. Ventricular pressures and volumes were varied by inflation of implanted vena caval and pulmonary artery occluders, and the functional significance of the two types of ventricular interaction, i.e., direct and series, was determined. The left ventricle was represented by a modified ellipsoidal geometry. Left ventricular stroke volume calculated from the dimension data correlated well with that measured directly from ascending aortic electromagnetic flow probes during all interventions (r greater than or equal to 0.96). Partial pulmonary artery occlusion significantly increased right ventricular diastolic and systolic pressures as compared to values obtained during control and venal caval occlusion. During pulmonary artery occlusion, latitudinal septal eccentricity was increased throughout the cardiac cycle compared to control and vena caval occlusion (P less than 0.05), indicating leftward interventricular septal shifting and significant alteration of left ventricular shape. The normalized diastolic pressure-volume curve was shifted to the left with pulmonary artery occlusion compared to control and indicated a decrease in left ventricular chamber compliance. However, when selected cardiac cycles with similar end-diastolic volumes from vena caval and pulmonary artery occlusions were compared, parameters of left ventricular systolic function (stroke volume, percent systolic shortening, peak aortic blood flow, peak left ventricular pressure, and its first derivative) remained relatively constant. These data suggest that mean myocardial fiber length is the major preload determinant of left ventricular systolic function independent of chamber pressure and shape, and that direct ventricular interaction mediated by interventricular septal shifting has minimal effects on systolic myocardial performance in this model. Thus, series ventricular interaction during acute imbalances in biventricular loading, where the output of the right ventricle determines the input of the left, seems to be far more important than direct interaction to the regulation of overall cardiac function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reference values of M-mode echocardiographic parameters and indices in conscious Labrador Retriever dogs

Breed-wise standard echocardiographic values in dogs have been reported as there is variation in body and chest conformation which limits the application of data of one breed for other breed. Labrador Retrievers being originated from hunting dogs, might have different echocardiographic values from standard normal range of other dog breeds. So, the present study was aimed to determine the M-mode...

متن کامل

The three-dimensional dynamic geometry of the left ventricle in the conscious dog.

The dynamic geometry of the left ventricle was assessed with the use of chronically implanted pulse-transit ultrasonic dimension transducers. The orientation of the transducers allowed the measurement of left ventricular minor and major axis diameters and equatorial wall thickness in the conscious dog. The left ventricle was modeled as a three-dimensional, prolate ellipsoidal shell. Left ventri...

متن کامل

Pericardial influences on ventricular filling in the conscious dog. An analysis based on pericardial pressure.

Twenty-five dogs were chronically instrumented to investigate the effects of the normal pericardium on cardiac function. Pulse-transit ultrasonic transducers were implanted to measure multiple ventricular dimensions. The pericardium was incised transversely at the base of the heart and precisely reapproximated, so as to disturb its characteristics minimally. One week later, the dogs were studie...

متن کامل

Postextrasystolic compliance of the left ventricle.

The effects of a single premature contraction (PC) on left ventricular diastolic distensibility was studied in man, in the conscious chronically instrumented dog, and in the isolated (isovolumic) blood perfused dog heart. In the isolated dog heart at a constant volume, there was no difference in end-diastolic pressure when control diastolic pressure was compared to that following a PC. In man a...

متن کامل

Mechanics of contraction and relaxation of the ventricle in experimental heart failure produced by rapid ventricular pacing in the conscious dog.

A model of heart failure produced by rapid ventricular pacing in the conscious dog instrumented with a conductance catheter to monitor instantaneous left ventricular volume has been developed. This experimental model is capable of analysis of the left ventricular pressure-volume relationship on a beat-to-beat basis, and has been used to assess ventricular function serially in the progress of he...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 52 1  شماره 

صفحات  -

تاریخ انتشار 1983