RF Coil Technology for Small-Animal MRI
نویسندگان
چکیده
A review of the theory, technology, and practice of RF coils for small-animal MRI is presented that includes a brief overview of MR S/N analysis and discussions of the various coils commonly used in small-animal MR – surface coils, linear volume coils, birdcages, and their derivatives. The scope is limited to mid-range coils – coils where the product (fd) of the frequency f and the coil diameter d is in the range of 2-30 MHz-m. Common applications include mouse brain and body coils from 125 MHz to 750 MHz, rat body coils up to 500 MHz, and small surface coils at all fields. In this regime, all the sources of loss (coil, capacitor, sample, shield, and transmission lines) are important. All such losses may be accurately captured in some modern full-wave 3D EM software, and new simulation results are presented for a selection of surface coils using Microwave Studio (MWS) 2006 by Computer Simulation Technology (CST), showing the dramatic importance of the “lift-off effect”. Standard linear circuit simulators have been shown to be useful in optimization of complex coil tuning and matching circuits. There appears to be considerable potential for trading S/N for speed using phased arrays, especially for a larger field of view. Circuit simulators are shown to be useful for optimal mismatching of ultra-low-noise preamps based on the E-PHEMT (Enhancement mode Pseudomorphic High Electron Mobility Transistor) for optimal coil decoupling in phased arrays. Cryogenically cooled rf coils are shown to offer considerable opportunity for future gains in S/N in smaller samples.
منابع مشابه
Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کامل3-D RF Coil Design Considerations for MRI
High-frequency coils are widely used in medical applications, such as Magnetic Resonance Imaging (MRI) systems. A typical medical MRI includes a local radio frequency transmit/receive coil. This coil is designed for maximum energy transfer or wave transfer through magnetic resonance. Mutual inductance is a dynamic parameter that determines the energy quantity to be transferred wirelessly by ele...
متن کاملCharacterization of Flexible RF Microcoil Dedicated to Surface Mri
In Magnetic Resonance Imaging (MRI), to achieve sufficient Signal to Noise Ratio (SNR), the electrical performance of the RF coil is critical. We developed a device (microcoil) based on the original concept of monolithic resonator. This paper presents the used fabrication process based on micromoulding. The dielectric substrates are flexible thin films of polymer, which allow the microcoil to b...
متن کاملActively Detunable 8-channel Small Animal Transceive Volume Array for 9.4T MRI systems
Introduction Ultra-high field MRI systems for small animals have seen a rapid development over recent years in a continuous effort to enhance SNR and spectral resolution of MRI images. To circumvent the associated high-field B1 inhomogeneity problem, methods such as RF shimming and Transmit SENSE have been proposed [1-2]. To benefit from the advantages of these techniques, dedicated phased-arra...
متن کاملDesign and comparison of two eight-channel transmit/receive radiofrequency arrays for in vivo rodent imaging on a 7 T human whole-body MRI system.
PURPOSE Magnetic resonance imaging (MRI) of rodents can be expected to be a growing application, particularly when translatory imaging research "from mouse to man" is envisioned. 7 T high-field human whole-body MR systems provide a powerful platform for high-resolution small animal imaging. For achieving adequate spatial resolution, dedicated radiofrequency coils have to be designed to provide ...
متن کامل