Modified technique for transscleral fixation of posterior chamber intraocular lenses

نویسندگان

  • Chongde Long
  • Yantao Wei
  • Zhaohui Yuan
  • Zhiqing Zhang
  • Xiaofeng Lin
  • Bingqian Liu
چکیده

BACKGROUND Suture exposure remains to be a potential problem of transscleral fixated posterior chamber intraocular lens (PCIOL). We report a modified technique to minimize the risk of suture exposure for the transscleral fixation of PCIOL. METHODS The modified surgical technique is as following: at first, two 3 mm × 4 mm square scleral pockets were created from groove incisions at opposite positions. A straight needle attached to a 10-0 polypropylene suture was passed through one incision groove. Then, a 27-Gauge hollow needle passed through the opposite sclera incision bed was used to retrieve the straight fine needle via its barrel. The sutures were tied to themselves after one more bite on the scleral bed. At last, the suture ends were left long (about 4 mm) and laid flat into corresponding laminar scleral pockets. This modified technique of PCIOL was performed in 48 post-traumatic aphakic vitrectomized eyes from 48 patients (47 male, one female) with mean age of 34.8 ± 14.8 years. Main outcome measures included best corrective visual acuity (BCVA), IOL decentration, IOL tilt, and postoperative complications. RESULTS The mean follow-up was 32.3 ± 10.8 months (3-67 months). The LogMAR BCVA remained stable, from a preoperative value of 0.46 ± 0.34 to postoperative 0.44 ± 0.34 (p = 0.69). Mild IOL tilt (5-10°) was observed in five eyes, and slight IOL decentration (0.5-1.0 mm) was seen in three cases. No case of suture exposure, suture breakage, IOL dislocation, or endophthalmitis was observed during the follow up period. CONCLUSION The modified technique allowed stable placement of PCIOLs in post-traumatic aphakic eyes with a wide range of follow-up. Our procedure might have the potential benefit to avoid suture exposure in scleral-fixated IOL implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surgical technique for transscleral fixation of a foldable posterior chamber intraocular lens.

The safety and efficacy of a modified technique for transscleral fixation of a foldable posterior chamber intraocular lens (IOL) for intracapsular aphakia (secondary IOL) or after complicated phacoemulsification was evaluated. All eyes had inadequate or no posterior capsular support. Follow-up was between 4 and 26 months (mean, 12 months). Uncorrected visual acuity improved (> 2 lines) in all p...

متن کامل

Modified transscleral fixation technique for refixation of dislocated intraocular lenses.

PURPOSE To evaluate the results of transscleral fixation of dislocated posterior chamber intraocular lenses (PC IOLs) by externalizing the haptics through a clear corneal incision. SETTING Department of Ophthalmology, Rassoul Akram Hospital, Iran University of Medical Sciences, Tehran, Iran. METHODS This retrospective interventional case series comprised 21 eyes (21 patients) in which a dis...

متن کامل

نتایج درازمدت نصب اسکلرال لنزهای داخل چشمی جابجا شده به روش خارج کردن هاپتیک از برش کوچک قرنیه

    Background & Aim: Several methods have been reported for refixation of dislocated intraocular lenses (IOLs). However, these methods are associated with some disadvantages including vitreous prolaps, vitreous traction, ocular collapse, intraocular hemorrhage, high astigmatism, and the need for complex intraocular maneuvers. The aim of this study was to evaluate the results of transscleral fi...

متن کامل

Transscleral suture fixation of posterior chamber intraocular lenses through the ciliary sulcus: endoscopic comparison of different suture techniques.

Two technical difficulties exist in transscleral suture fixation of posterior chamber intraocular lenses (PCL) in the ciliary sulcus: first, exact needle penetration of the sulcus and second, exact positioning of the PCL haptics in the sulcus. We used, for the first time, intraocular endoscopy to visualize the site of needle penetration and the final location of the haptics in patients. It turn...

متن کامل

One-Haptic Fixation of Posterior Chamber Intraocular Lenses without Scleral Flaps

Purpose. To assess visual results and complications of a modified technique of posterior chamber intraocular lenses (PC IOLs) in aphakic eyes without scleral flaps. Methods. Modified one-haptic scleral fixation was performed in one eye each of 25 patients with aphakia and insufficient capsule support. Follow-up period was six months. Outcome measures included best-corrected visual acuity, intra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -