Flux detectors versus concentration detectors: two types of chemoreceptors.

نویسنده

  • K E Kaissling
چکیده

Dose-response curves relating the external stimulus concentration to receptor occupancy differ in two types of chemoreceptor organs. In 'concentration detectors' the receptor molecules at the receptor cell membrane are directly exposed to the external stimulus concentration; these organs exhibit the well-known hyperbolic dose-response relationship reflecting the association-dissociation of stimulus and receptor molecules. In contrast, 'flux detectors' accumulate the stimulus molecules in a perireceptor compartment. In flux detectors, deactivation of stimulus molecules may be in balance with arrival, as a prerequisite for producing a constant effective stimulus concentration at constant adsorptive flux of stimulus molecules. In a simple model of a flux detector in which receptor molecules themselves catalyze the deactivation, the dose-response relationship is linear. It reflects the rate of stimulus deactivation. If the deactivation is catalyzed by a separate enzyme, the dose-response relationship can be close to hyperbolic, or linear. In all cases, the receptor molecules are maximally occupied if the adsorptive flux equals or exceeds the maximum rate of stimulus deactivation. The time course of the receptor potential recorded from moths' pheromone receptors depends on the odor compound, which suggests that a peripheral process, possibly the stimulus deactivation, is the slowest, rate-limiting process of the transduction cascade. Further evidence comes from experiments with stimuli oversaturating the mechanism responsible for the decline of the receptor potential.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

GABA-mediated membrane oscillations as coincidence detectors for enhancing synaptic efficacy in the developing hippocampus

Spontaneously occurring neuronal oscillations constitute a hallmark of developmental networks. They have been observed in the retina, neocortex, hippocampus, thalamus and spinal cord. In the immature hippocampus the so-called ‘giant depolarizing potentials’ (GDPs) are network-driven membrane oscillations characterized by recurrent membrane depolarization with superimposed fast action potentials...

متن کامل

GABA-mediated membrane oscillations as coincidence detectors for enhancing synaptic efficacy in the developing hippocampus

Spontaneously occurring neuronal oscillations constitute a hallmark of developmental networks. They have been observed in the retina, neocortex, hippocampus, thalamus and spinal cord. In the immature hippocampus the so-called ‘giant depolarizing potentials’ (GDPs) are network-driven membrane oscillations characterized by recurrent membrane depolarization with superimposed fast action potentials...

متن کامل

ar X iv : 0 90 3 . 30 39 v 1 [ he p - ph ] 1 8 M ar 2 00 9 Physics with near detectors at a neutrino factory

We discuss the impact of near detectors at a neutrino factory both on standard oscillation and non-standard interaction measurements. Our systematics treatment includes cross section errors, flux errors, and background uncertainties, and our near detector fluxes include the geometry of the neutrino source and the detector. Instead of a specific detector concept, we introduce qualitatively diffe...

متن کامل

ساخت و آزمایش آشکارساز ترموپیلی نوترون در ستون حرارتی رآکتور تحقیقاتی تهران

Upon increasing needs and vast application of neutron detectors, especially in nuclear reactors and growing number of linear accelerators, design and manufacturing of neutron detectors is a serious demand. The aim of this project is building neutron detectors capable of compensating gamma and temperature response in a radiation media. A special thermocouple coated with Boron carbide at the junc...

متن کامل

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chemical senses

دوره 23 1  شماره 

صفحات  -

تاریخ انتشار 1998