Evaluation of an automated safety surveillance system using risk adjusted sequential probability ratio testing

نویسندگان

  • Michael E. Matheny
  • Sharon-Lise T. Normand
  • Thomas P. Gross
  • Danica Marinac-Dabic
  • Nilsa Loyo-Berrios
  • Venkatesan D. Vidi
  • Sharon Donnelly
  • Frederic S. Resnic
چکیده

BACKGROUND Automated adverse outcome surveillance tools and methods have potential utility in quality improvement and medical product surveillance activities. Their use for assessing hospital performance on the basis of patient outcomes has received little attention. We compared risk-adjusted sequential probability ratio testing (RA-SPRT) implemented in an automated tool to Massachusetts public reports of 30-day mortality after isolated coronary artery bypass graft surgery. METHODS A total of 23,020 isolated adult coronary artery bypass surgery admissions performed in Massachusetts hospitals between January 1, 2002 and September 30, 2007 were retrospectively re-evaluated. The RA-SPRT method was implemented within an automated surveillance tool to identify hospital outliers in yearly increments. We used an overall type I error rate of 0.05, an overall type II error rate of 0.10, and a threshold that signaled if the odds of dying 30-days after surgery was at least twice than expected. Annual hospital outlier status, based on the state-reported classification, was considered the gold standard. An event was defined as at least one occurrence of a higher-than-expected hospital mortality rate during a given year. RESULTS We examined a total of 83 hospital-year observations. The RA-SPRT method alerted 6 events among three hospitals for 30-day mortality compared with 5 events among two hospitals using the state public reports, yielding a sensitivity of 100% (5/5) and specificity of 98.8% (79/80). CONCLUSIONS The automated RA-SPRT method performed well, detecting all of the true institutional outliers with a small false positive alerting rate. Such a system could provide confidential automated notification to local institutions in advance of public reporting providing opportunities for earlier quality improvement interventions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Do delays in data availability limit the implementation of near real‐time vaccine safety surveillance using the Clinical Practice Research Datalink?

PURPOSE Near real-time vaccine safety surveillance (NRTVSS) using electronic health records has been used to detect timely vaccine safety signals. Trial implementation of NRTVSS using the Clinical Practice Research Datalink (CPRD) has shown that there is limited power to detect safety signals for rare events. Delays in recording outcomes and receiving data influence the power and timeliness to ...

متن کامل

Risk-adjusted sequential probability ratio test control chart methods for monitoring operator and institutional mortality rates in interventional cardiology.

BACKGROUND The objective of this study was to evaluate risk-adjusted sequential probability ratio test control charts for the detection of significant discrepancies between institution or individual interventional cardiologist postprocedural mortality rates and national or local event rate expectations. METHODS Eight thousand nine hundred forty-two percutaneous coronary interventional procedu...

متن کامل

Real-time vaccine safety surveillance for the early detection of adverse events.

BACKGROUND Rare but serious adverse events associated with vaccines or drugs are often nearly impossible to detect in prelicensure studies and require monitoring after introduction of the agent in large populations. Sequential testing procedures are needed to detect vaccine or drug safety problems as soon as possible after introduction. OBJECTIVE To develop and evaluate a new real-time survei...

متن کامل

Prospective influenza vaccine safety surveillance using fresh data in the Sentinel System†

PURPOSE To develop the infrastructure to conduct timely active surveillance for safety of influenza vaccines and other medical countermeasures in the Sentinel System (formerly the Mini-Sentinel Pilot), a Food and Drug Administration-sponsored national surveillance system that typically relies on data that are mature, settled, and updated quarterly. METHODS Three Data Partners provided their e...

متن کامل

An Experimental Assessment of Compression Ratio and Evaluation of Aluminium Cylinder Head in Bi-Fuel(Gasoline+CNG) Engines

The first step in dealing with the behavior of an engine on NG mode is the installation of a suitable gas fueling system on the engine. Two generations of gas fueling systems which were studied and installed on research engine were Mixer type and Sequential system type. The results, including performance, emissions and fuel consumption, were recorded and analyzed. The results showed that the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -