Camera-based pulse-oximetry - validated risks and opportunities from theoretical analysis.
نویسندگان
چکیده
Camera-based pulse-oximetry has recently shown to be feasible, even when the signal is corrupted by noise and motion artifacts. Earlier work showed that using three instead of the common two wavelengths improves robustness of the measurement, however without a thorough investigation on the optimal wavelength selection. We therefore performed a search to identify these wavelengths to further improve the robustness of the measurement. Besides motion, it is empirically known that there are several other factors that influence the measurement leading to falsely-low or falsely-high SpO2 readings. These factors include the presence of dyshemoglobins or other species. In this paper, we use a theoretical skin-model to study how these factors influence the measurement, and how a proper wavelength selection can reduce the impact on the measurement. Additionally, we show that adding a third wavelength does not only improve robustness, but can also be exploited to create a reliability index for the measurement. Finally, we show that the presence of dyshemoglobins in arterial blood can not only be detected but also quantified. We illustrate this by comparing the estimated COHb levels of a small group of smokers and non-smokers, which typically have different CO-levels.
منابع مشابه
Can we Replace Arterial Blood Gas Analysis by Pulse Oximetry in Neonates with Respiratory Distress Syndrome, who are Treated According to INSURE Protocol?
Neonates with respiratory distress syndrome (RDS), who are treated according to INSURE protocol; require arterial blood gas (ABG) analysis to decide on appropriate management. We conducted this study to investigate the validity of pulse oximetry instead of frequent ABG analysis in the evaluation of these patients. From a total of 193 blood samples obtained from 30 neonates <1500 grams with RDS,...
متن کاملA Three-Wavelength Pulse Oximeter for Carboxyhemoglobin Determination
Pulse oximetry measures the relative concentration of arterial oxygenated hemoglobin and reduced hemoglobin. This paper presents the design of a pulse oximeter, which measures the presence of a third substance, carboxyhemoglobin (HbCO), by unfiltered LEDs at 660 nm, 810 nm, and 940 nm. Background information is given on the theory of pulse oximetry. Theoretical approximations and calculations w...
متن کاملCalibration of Contactless Pulse Oximetry
BACKGROUND Contactless, camera-based photoplethysmography (PPG) interrogates shallower skin layers than conventional contact probes, either transmissive or reflective. This raises questions on the calibratability of camera-based pulse oximetry. METHODS We made video recordings of the foreheads of 41 healthy adults at 660 and 840 nm, and remote PPG signals were extracted. Subjects were in norm...
متن کاملEvaluation and Improvement of Knowledge of Medical staff on Pulse Oximetry in Educational Hospitals
Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...
متن کاملEvaluation and Improvement of Knowledge of Medical staff on Pulse Oximetry in Educational Hospitals
Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomedical optics express
دوره 9 1 شماره
صفحات -
تاریخ انتشار 2018