Proper Angle of Sono-guided Central Venous Line Insertion
نویسندگان
چکیده
INTRODUCTION Determining the proper angle for inserting central venous catheter (CV line) is of great importance for decreasing the complications and increasing success rate. The present study was designed to determine the proper angle of needle insertion for internal jugular vein catheterization. METHODS In the present case series study, candidate patients for catheterization of the right internal jugular vein under guidance of ultrasonography were studied. At the time of proper placing of the catheter, photograph was taken and Auto Cad 2014 software was used to measure the angles of the needle in the sagittal and axial planes, as well as patient's head rotation. RESULT 114 patients with the mean age of 56.96 ± 14.71 years were evaluated (68.4% male). The most common indications of catheterization were hemodialysis (55.3%) and shock state (24.6%). The mean angles of needle insertion were 102.15 ± 6.80 for axial plane, 36.21 ± 3.12 for sagittal plane and the mean head rotation angle was 40.49 ± 5.09. CONCLUSION Based on the results of the present study it seems that CV line insertion under the angles 102.15 ± 6.80 degrees in the axial plane, 36.21 ± 3.12 in the sagittal plane and 40.49 ± 5.09 head rotation yield satisfactory results.
منابع مشابه
Comparison Between Open and Ultrasonography Guided Venous Access Ports in Children with Malignancy
Background: Long-term central venous access is used in children for various reasons specially for delivering chemotherapy. Since vessels in children have smaller diameters, they are more prone to injury and complications such as thrombosis. Different methods are used for implantation of port-a-cath in children. We aimed to compare the complications of insertion of central venous access ports be...
متن کاملESPEN Guidelines on Parenteral Nutrition: central venous catheters (access, care, diagnosis and therapy of complications).
When planning parenteral nutrition (PN), the proper choice, insertion, and nursing of the venous access are of paramount importance. In hospitalized patients, PN can be delivered through short-term, non-tunneled central venous catheters, through peripherally inserted central catheters (PICC), or - for limited period of time and with limitation in the osmolarity and composition of the solution -...
متن کاملA new central venous access in Emergency Department: ultrasound-guided infraclavicular axillary vein
Results 52 year old woman addicted to parenteral drugs, stage C3 HIV with 2 weeks duration fever. On arrival had malaise, hypotensive, febrile, tachycardic... it was not possible to catheterize a peripheral vein we performed a central line cannulation: ultrasound-guided infraclavicular axillary vein. Less arterio-venous overlap and a greater distance between artery and vein and from vein to rib...
متن کاملUltrasound guided central vascular access in neonates, infants and children.
Ultrasound guided central venous cannulation is rapidly becoming the standard technique for achieving a central line in neonates, infants and children. Older techniques such as surgical cutdown and 'blind' percutaneous venipuncture have many disadvantages: they are time consuming, vein consuming and/or associated with dangerous immediate or late complications. On the other hand, ultrasound has ...
متن کاملحل مشکل جاگذاری کاتتر ورید مرکزی با استفاده از کاتتر وریدی: مقاله تکنیکال
Insertion of central venous catheter is an accepted method for hemodynamic monitor-ring, drug and fluid administration, intravenous access, hemodialysis and applying cardiac pace-maker in hospitalized patients. This procedure can be associated with severe complications. The aim of this article is to provide a practical approach to prevent catheter malposition in states that the guide wire will ...
متن کامل