A Portable Millivoltmeter *

نویسندگان

  • Marvin G. Schorr
  • Harold Lamport
چکیده

The instrument to be described was developed for the measurement of bioelectric potentials, especially those found on the skin. As such it was desired that it be portable, not dependent on the availability of electric current, and that, because of its biological applications, the input resistance be at least 10 megohms and that grid current through this resistance be less than 1 0-10 amperes within the 100 millivolt range of the instrument. The sensitivity required was 1 millivolt per scale division of a portable galvanometer (sensitivity about 0.040 microamperes per scale division). Other millivoltmeters1 utilize large power type tubes, with high grid-to-plate transconductance, operated at reduced voltages to achieve stability and low grid current. These circuits have several disadvantages where portability is of importance: first, because of their large current requirements, a heavy-duty B battery for the plate circuit and a storage battery for the filaments become necessary; second, despite the use of these large batteries, the high current drain still causes enough instability so that a balanced bridge circuit is needed to eliminate 'battery variations; third, in achieving the requisite stability, the bridge doubles the current requirements while halving the sensitivity of the instrument as compared to that of a single tube. While less sensitive tubes (lower transconductance) designed for dry cell operation may be chosen,2 they also must employ the balanced circuit with its attendant disadvantages. A new series of miniature tubest is well suited to portable battery powered apparatus. The filament draws less than 15 milliamperes from a single 1.5 volt cell. The plate current of the triode VW-32 is about 250 microamperes with a 10.5 volt B battery. Because of these low current requirements, it was found that flashlight cells for the plate supplv and a single No. 6 type dry cell for the filament

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Static and Dynamic Analyze of the an Aluminum Pad used as Portable Roadway

Due to geographic and climatic conditions in mountainous northwest area, Roads in these areas are often covered with snow, ice and mud. Hence Transportation of equipment and soldiers encounter hardship and difficulties in rural area and specially outposts. To solve these problems, it is needed to fabricate portable roadway or traction mats. These high strength mats cover surface of roads and ar...

متن کامل

An Experimental Investigation of Enclosure’s Effect on Noise Reduction in Portable Generators (Technical Note)

The portable generators are the main means of compensating the shortage of national electricity power as in Iraq. However, their noise causes a huge disturbance, uncomforting and loss of concentration of the nearby resident. This problem requires a solution because most shops and residential houses use generators. Covering method is a simple and relatively low cost one for reduction of generato...

متن کامل

Using 137Cs Technique to Investigate Soil Redistribution Rates by Portable HPGe (Case Studies, Kachik Paired Subcatchments)

137Cs technique for determining soil particles redistribution is of tremendous importance considered by most soil and water conservation experts. Due to time and monetary limitations for spectrometry in the lab, a portable High Pure Germanium Detector was used in this study. For this, Kachik paired subcatchments were chosen and 60 positions in each subcatchment were used for spectrometry analys...

متن کامل

Design and Fabrication of a Portable 1-DOF Robotic Device for Indentation Tests

There are many tactile devices for indentation examinations to measure mechanical properties of tissue. The purpose of this paper is to develop a portable indentation robotic device to show its usability for measuring the mechanical properties of a healthy abdominal tissue. These measurements will help to develop suitable mathematical models representing abdominal tissue. A 1-DOF portable robot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Yale Journal of Biology and Medicine

دوره 18  شماره 

صفحات  -

تاریخ انتشار 1946