Laryngeal mask airway size selection in males and females: ease of insertion, oropharyngeal leak pressure, pharyngeal mucosal pressures and anatomical position.

نویسندگان

  • J Brimacombe
  • C Keller
چکیده

We have compared ease of insertion, oropharyngeal leak pressure, directly measured pharyngeal mucosal pressure and anatomical position (assessed fibreoptically) for the size 4 and size 5 laryngeal mask airway (LMA) in 20 male and 20 female patients. Microchip pressure sensors were attached to the LMA at locations corresponding to the piriform fossa, hypopharynx, base of the tongue, lateral and posterior pharynx, and the oropharynx. Oropharyngeal leak pressure, mucosal pressure and fibreoptic position were recorded during inflation of the cuff from 0 to 30 ml in 10-ml increments. In males, oropharyngeal leak pressure over the inflation range was higher for size 5 (21 vs 17 cm H2O; P = 0.01); mucosal pressure over the inflation range was higher in the posterior pharynx for size 4 (7 vs 2 cm H2O; P = 0.007), and higher in the piriform fossa (8 vs 5 cm H2O; P = 0.003) and hypopharynx (9 vs 5 cm H2O; P = 0.003) for size 5. In females, oropharyngeal leak pressure over the inflation range was the same (21 vs 21 cm H2O), but mucosal pressure over the inflation range was higher in the piriform fossa (21 vs 8 cm H2O; P = 0.003) and posterior pharynx (4 vs 2 cm H2O; P = 0.004) for size 4, and higher in the lateral pharynx (5 vs 1 cm H2O; P = 0.01) and oropharynx (11 vs 5 cm H2O; P = 0.009) for size 5. The distribution of mucosal pressure was different for size 4 between males and females, but not for size 5. For both males and females, fibreoptic position was similar. We conclude that the size 5 LMA is optimal in males, but either size is suitable for females. The shape of the pharynx may be different between males and females.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of Ambu AuraGain™ with ProSeal™ laryngeal mask airway in patients undergoing laparoscopic cholecystectomy

BACKGROUND AND AIMS Second generation supraglottic airways are increasingly being used in surgical patients undergoing laparoscopic surgery. Preventing aspiration at higher airway pressures may be at the expense of a higher cuff pressure which can impair mucosal perfusion. We attempted to elucidate whether Ambu AuraGain™ (AAU) would provide a higher oropharyngeal leak pressure (OLP) with a lowe...

متن کامل

Sex-based ProSeal laryngeal mask airway size selection: a randomized crossover study of anesthetized, paralyzed male and female adult patients.

UNLABELLED We compared the Size 4 and 5 ProSeal laryngeal mask airway (PLMA) in men and the Size 3 and 4, and 4 and 5 PLMA in women in terms of 1) ease of insertion, 2) oropharyngeal leak pressure (OLP), 3) ease of ventilation at a tidal volume of 10 mL/kg, 4) gas exchange, 5) location of gas leak, 6) anatomic position of the airway and drain tube, and 7) mucosal injury. Thirty male and 60 fema...

متن کامل

The laryngeal mask airway Supreme--a single use laryngeal mask airway with an oesophageal vent. A randomised, cross-over study with the laryngeal mask airway ProSeal in paralysed, anaesthetised patients.

The LMA Supreme is a new extraglottic airway device which brings together features of the LMA ProSeal, Fastrach and Unique. We test the hypothesis that ease of insertion, oropharyngeal leak pressure, fibreoptic position and ease of gastric tube placement differ between the LMA ProSeal and the LMA Supreme in paralysed anesthetised patients. Ninety-three females aged 19-71 years were studied. Bot...

متن کامل

Influence of cuff volume on oropharyngeal leak pressure and fibreoptic position with the laryngeal mask airway.

We studied the size 4 laryngeal mask airway (LMA) to test the hypothesis that oropharyngeal leak pressure and fibreoptic position improves with increasing cuff volume. After LMA insertion, 50 anaesthetized adult patients had the cuff inflated in 5-ml increments to 40 ml. Oropharyngeal leak pressure was optimal at 15 ml and decreased at higher volumes. The fibreoptic position was optimal at 0-20...

متن کامل

Influence of neuromuscular block, mode of ventilation and respiratory cycle on pharyngeal mucosal pressures with the laryngeal mask airway.

We tested the hypothesis that the pressure exerted by the laryngeal mask airway (LMA) against the pharyngeal mucosa varied with neuromuscular block, mode of ventilation and the respiratory cycle. We studied 20 anaesthetized adult patients. Microchip sensors were attached to a size 5 LMA at locations approximately corresponding to the base of the tongue, hypopharynx, lateral pharynx, oropharynx,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 82 5  شماره 

صفحات  -

تاریخ انتشار 1999