Carotid duplex ultrasound velocity measurements versus intravascular ultrasound in detecting carotid in-stent restenosis.

نویسندگان

  • Bryan P Yan
  • David J Clark
  • Michael R Jaff
  • Thomas J Kiernan
  • Robert M Schainfeld
  • Sara Lessio
  • Kenneth Rosenfield
چکیده

BACKGROUND Duplex ultrasonography criteria for assessing the severity of carotid artery (CA) in-stent restenosis are not well established. METHODS AND RESULTS We analyzed 39 patients (40 CAs) who underwent CA stenting with baseline and 6-month follow-up carotid duplex ultrasonography and intravascular ultrasound. Intravascular ultrasound measurements included minimum luminal diameter, percent diameter, and lumen area stenosis. Duplex ultrasonography measurements included peak systolic velocity (PSV), percentage change in PSV, end-diastolic velocity (EDV), and internal-to-common CA PSV ratio (ICA/CCA). Receiver operating characteristic curves assessed each duplex measurement to detect >or=50% diameter, >or=75% lumen area stenosis, and minimum luminal diameter <3 mm at follow-up. At 6-month intravascular ultrasound follow-up, >or=50% diameter and >or=75% lumen area CA in-stent restenosis occurred in 20% and 25%, respectively; minimum luminal diameter <3 cm occurred in 48%. Area under receiver operating characteristic curves for PSV, EDV, and ICA/CCA were 0.85, 0.96, and 0.89 for >or=50% diameter stenosis and 0.89, 0.93, and 0.88 for >or=75% lumen area stenosis, respectively. Optimal PSV, EDV, and ICA/CCA criteria to detect >or=50% diameter and >or=75% lumen area CA in-stent restenosis were greater compared with those for native CA. A >98% increase in PSV had the highest specificity, whereas the combination of EDV >41 cm/s and ICA/CCA >2 had the highest sensitivity in detecting >or=75% lumen area CA in-stent restenosis. CONCLUSIONS PSV, EDV, and ICA/CCA PSV ratio were good discriminators for detecting significant diameter and lumen area greater compared with those for native CA. The combination of duplex velocity criteria increases diagnostic accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Morphological and hemodynamic patterns of carotid stenosis treated by endarterectomy with patch closure versus stenting: a duplex ultrasound study

OBJECTIVES A duplex ultrasound study was performed to investigate morphological and hemodynamic patterns of carotid stenoses treated by endarterectomy with patch closure versus stenting. MATERIALS AND METHOD Twenty-nine carotid stenoses were treated with stenting and 65 with patch closure. Duplex ultrasound parameters (luminal diameter, mm; peak systolic velocity and end-diastolic velocity, c...

متن کامل

Mechanisms and predictors of carotid artery stent restenosis: a serial intravascular ultrasound study.

OBJECTIVES The aim of this study was to determine the mechanisms and predictors of carotid artery restenosis after carotid artery stenting (CAS) using serial intravascular ultrasound (IVUS) imaging. BACKGROUND Carotid artery stenting is increasingly used to treat high-grade obstructive carotid disease, but our knowledge of carotid in-stent restenosis and remodeling remains limited. METHODS ...

متن کامل

Optimal cut-off criteria for duplex ultrasound for the diagnosis of restenosis in stented carotid arteries: Review and protocol for a diagnostic study

BACKGROUND Carotid angioplasty with stenting is a relatively new, increasingly used, less-invasive treatment for the treatment of symptomatic carotid artery stenosis. It is being evaluated in ongoing and nearly finished randomized trials. An important factor in the evaluation of stents is the occurrence of in-stent restenosis. An un-stented carotid artery is likely to have a more elastic vessel...

متن کامل

Standardized ultrasound evaluation of carotid stenosis for clinical trials: University of Washington Ultrasound Reading Center

INTRODUCTION Serial monitoring of patients participating in clinical trials of carotid artery therapy requires noninvasive precision methods that are inexpensive, safe and widely available. Noninvasive ultrasonic duplex Doppler velocimetry provides a precision method that can be used for recruitment qualification, pre-treatment classification and post treatment surveillance for remodeling and r...

متن کامل

Standardization of carotid ultrasound: a hemodynamic method to normalize for interindividual and interequipment variability.

BACKGROUND AND PURPOSE Accurate carotid Doppler examination is an important issue in the light of large endarterectomy trials, but recommended cutoff values for detection of >70% stenosis vary widely. Standardization of diagnostic criteria should consider patient variation and instrument variability. METHODS We prospectively analyzed various Doppler parameters in 44 patients undergoing caroti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 2 5  شماره 

صفحات  -

تاریخ انتشار 2009