MR spectroscopy of the human brain with enhanced signal intensity at ultrashort echo times on a clinical platform at 3T and 7T.

نویسندگان

  • Ralf Mekle
  • Vladimír Mlynárik
  • Giulio Gambarota
  • Martin Hergt
  • Gunnar Krueger
  • Rolf Gruetter
چکیده

Recently, the spin-echo full-intensity acquired localized (SPECIAL) spectroscopy technique was proposed to unite the advantages of short TEs on the order of milliseconds (ms) with full sensitivity and applied to in vivo rat brain. In the present study, SPECIAL was adapted and optimized for use on a clinical platform at 3T and 7T by combining interleaved water suppression (WS) and outer volume saturation (OVS), optimized sequence timing, and improved shimming using FASTMAP. High-quality single voxel spectra of human brain were acquired at TEs below or equal to 6 ms on a clinical 3T and 7T system for six volunteers. Narrow linewidths (6.6 +/- 0.6 Hz at 3T and 12.1 +/- 1.0 Hz at 7T for water) and the high signal-to-noise ratio (SNR) of the artifact-free spectra enabled the quantification of a neurochemical profile consisting of 18 metabolites with Cramér-Rao lower bounds (CRLBs) below 20% at both field strengths. The enhanced sensitivity and increased spectral resolution at 7T compared to 3T allowed a two-fold reduction in scan time, an increased precision of quantification for 12 metabolites, and the additional quantification of lactate with CRLB below 20%. Improved sensitivity at 7T was also demonstrated by a 1.7-fold increase in average SNR (= peak height/root mean square [RMS]-of-noise) per unit-time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-Quality MR Spectroscopy of the Human Brain with Full Signal Intensity at Echo Times Below 6 ms on a Clinical Platform at 3T and 7T

using a quadrature surface coil. Upper Left: 3T, VOI=20x20x20 mm in parietal WM, TR/TE=2000/6, BW=2kHz, 256 scans; Lower Left: 7T, VOI=30x15x30 mm in occipital GM, TR/TE=4000/5.7, BW=4kHz, 64 scans. Data processing consisted of zero-filling up to 16-k data points, shifted Gaussian weighting of the FID, Fourier transformation, and phase correction. Right: Corresponding fitted curves using LCMode...

متن کامل

Effect of Echo Time on the Maximum Relationship between Contrast Agent Concentration and Signal Intensity Using FLAIR Sequence

Introduction Contrast-enhanced fluid-attenuated inversion recovery (FLAIR) is one of the MRI sequences that can be used for detection and evaluation of pathological changes in the brain. In this work, we have studied the effect of different echo times (TE) on the maximum relationship between signal intensity and concentration of the contrast agent using the FLAIR sequence. Materials and Methods...

متن کامل

Improved Spectral Quality Through Enhanced Shimming on a Clinical Platform at 3T and 7T

Introduction Increased spectral resolution and signal-to-noise ratio (SNR) and additional metabolite information not available at B0 = 1.5T are some of the benefits of magnetic resonance spectroscopy (MRS) at higher fields (≥3T) that enhance its attractiveness as an investigational tool for clinical use. However, to obtain high-quality MR spectra, reliable localized shimming is an essential pre...

متن کامل

Ultrashort Echo Time Imaging of Cortical Bone at 7 Tesla Field Strength

Introduction MRI at ultra-high field (UHF) strength of 7 Tesla has been increasingly used and optimized for in vivo applications over the past few years. In particular, the increased signal to noise ratio (SNR) renders this new modality very attractive for imaging soft tissues in the human body. More solid or semi-solid tissues such as trabecular and cortical bone provide little to no signal in...

متن کامل

T1 and T2 Metabolite Relaxation Times in Normal Brain at 3T and 7T

Proton magnetic resonance spectroscopy (MRS) is a powerful noninvasive tool that has been widely used for the assessment of brain metabolites and the investigation of normal and abnormal metabolism in brain tissue. With the availability of improved hardware and acquisition techniques, in vivo single-voxel 1H-MRS and multivoxel magnetic resonance spectroscopic imaging (MRSI) can offer new possib...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 61 6  شماره 

صفحات  -

تاریخ انتشار 2009