Ultra-Fast Timing with Plastic Scintillators
نویسندگان
چکیده
As precursor to HISPEC, the upcoming PreSPEC campaign incorporates the commissioning of the first version of the LYCCA (Lund-York-Cologne-CAlorimeter) detector system called LYCCA-0. The LYCCA detector is a Time-of-Flight (ToF), ∆E, E set-up designed to unambigiously identify nuclear reaction products by their mass A, and charge Z . For this to be possible up to masses around A = 100, the total time resolution of the ToF measurement should be on the order of 100 ps FWHM or better [1]; comprised of 50 ps and 80 ps FWHM for the start and stop detctor, respectively. Mainly two timing options are deemed viable; polycrystaline CVD diamond detectors and fast plastic scintillators. In the LYCCA-0 set-up the diamond detectors are to be tested as ToF-start detector, while a large-area fast plastic scintillator is to give the ToF-stop signal. This report outlines first results from proof of principle tests of the fast plastic scintillator investigated both in the laboratory using a laser and in-beam during a test experiment at the FRS [2].
منابع مشابه
Optical simulation and experimental measurement of gamma ray energy spectrum of plastic scintillators with different sizes
The application of large plastic scintillators is widely increasing in the different areas of industry, medicine and security due to technical and economic advantages. One of the main disadvantages of these detectors is the unknown position of Compton edge at gamma ray spectrum. In this research, GEANT4/GATE code has been used to simulate the gamma ray spectrum for different volumes of large pl...
متن کاملInvestigation of Lanthanum Scintillators for 3-D PET
The main thrust for this work is the investigation and design of a positron emission tomography (PET) scanner based on new Lanthanum Halide scintillators. In three–dimensional (3-D) PET the major limitations are scanner dead-time and ability to reject randoms and scatter. Therefore, to reach the full potential of 3-D PET requires a scintillator with good timing resolution and good energy resolu...
متن کاملA feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators
We present a study of the application of the Jagiellonian positron emission tomograph (J-PET) for the registration of gamma quanta from decays of ortho-positronium (o-Ps). The J-PET is the first positron emission tomography scanner based on organic scintillators in contrast to all current PET scanners based on inorganic crystals. Monte Carlo simulations show that the J-PET as an axially symmetr...
متن کاملApplication of WLS strips for position determination in strip PET tomograph based on plastic scintillators
A method of determination of a gamma quantum absorption point in a plastic scintillator block using a matrix of wavelength-shifting (WLS) strips is proposed. Application of this method for improvement of position resolution in newly proposed PET detectors based on plastic scintillators is presented. The method enables to reduce parallax errors in reconstruction of images which occurs in the pre...
متن کاملFeasibility of Ultra-Thin Fiber-Optic Dosimeters for Radiotherapy Dosimetry
In this study, prototype ultra-thin fiber-optic dosimeters were fabricated using organic scintillators, wavelength shifting fibers, and plastic optical fibers. The sensor probes of the ultra-thin fiber-optic dosimeters consisted of very thin organic scintillators with thicknesses of 100, 150 and 200 μm. These types of sensors cannot only be used to measure skin or surface doses but also provide...
متن کامل