Myocardial blood flow distribution in patients with ischemic heart disease or dilated cardiomyopathy undergoing heart transplantation.
نویسندگان
چکیده
BACKGROUND The present investigation was designed to obtain an absolute measurement of myocardial blood flow and of its transmural distribution in ischemic heart disease and idiopathic dilated cardiomyopathy and to provide a reference standard for cardiac imaging in nuclear cardiology. METHODS AND RESULTS Regional myocardial blood flow and its transmural distribution were estimated by the reference microsphere method in eight patients with idiopathic dilated cardiomyopathy (n = 4) or ischemic heart disease (n = 4) during heart transplant procedure. Before aortic clamping, 99mTc-labeled human albumin microspheres were injected into the left atrium while arterial blood was sampled from the aorta at a constant rate. No complications were observed during or after the procedure. From the excised heart, myocardial slices for gamma camera imaging and well counting analysis were obtained. Myocardial blood flow was assessed by a well counter, correlated with the extent of fibrosis expressed as collagen per total tissue proteins obtained from 4-hydroxyproline and glycine as determined by high-performance liquid chromatography. Microsphere distribution, as seen by gamma camera images in a different slice, was correlated with the extent of fibrosis assessed by histological analysis of the same myocardial specimen. Mean transmural myocardial blood flow was 0.49 +/- 0.17 and 0.38 +/- 0.15 mL.min-1 x g-1 in idiopathic dilated cardiomyopathy and ischemic heart disease, respectively (P < .01). Endocardial-to-epicardial flow ratio was lower in ischemic heart disease than in idiopathic dilated cardiomyopathy patients (0.99 +/- 0.33 versus 1.16 +/- 0.30, P < .05). Mean myocardial fibrosis was 9 +/- 6% in idiopathic dilated cardiomyopathy and 25 +/- 28% in ischemic heart disease. In both groups, no correlation was found between myocardial blood flow values and the extent of fibrosis. In ischemic heart disease, regional myocardial blood flow was not significantly affected by the severity of coronary stenosis (< or = 70% or > 70%) either in the endocardium (0.44 +/- 0.24 versus 0.36 +/- 0.16 mL.min-1 x g-1, P = NS) or in the epicardium (0.50 +/- 0.33 versus 0.38 +/- 0.33 mL.min-1 x g-1, P = NS). By gamma camera imaging, transmural microsphere distribution appeared more homogeneous in idiopathic dilated cardiomyopathy than in ischemic heart disease (mean coefficient variation, 18% and 27%, respectively; P < .02); the severity of perfusion impairment did not correlate with the extent of fibrosis evaluated by histological criteria. CONCLUSIONS Heart transplant surgery offers a valuable model to assess absolute myocardial perfusion in human heart failure. Myocardial blood flow is markedly depressed in failing hearts of both ischemic heart disease and idiopathic dilated cardiomyopathy patients; a different transmural myocardial blood flow distribution is observed in ischemic heart disease than in idiopathic dilated cardiomyopathy, with prevalent endocardial perfusion in the latter but not the former condition. In patients with end-stage heart failure, myocardial blood flow appears to be similarly impaired in fibrotic and viable regions. Mechanisms other than myocardial fibrosis and coronary lesions appear to operate in determining myocardial blood flow impairment in heart failure.
منابع مشابه
The value of myocardial perfusion imaging in differentiating between idiopathic dilated cardiomyopathy from the ischemic form [Persian]
Introduction: Differentiating between ischemic cardiomyopathy (ICM) and idiopathic dilated cardiomyopathy (IDCM) is important as coronary revascularization can improve prognosis in the ischemic subgroup. Due to inherent problems of coronary angiography in patients with depressed ejection fraction (EF) introducing a noninvasive tool to diagnose those who will benefit from angiography seems...
متن کاملEvaluation of transesophageal echocardiography in detecting cardiac sources of emboli in ischemic stroke patients
Background: Embolus is one of the causes of ischemic stroke that can be due to cardiac sources such as valvular heart diseases and atrial fibrillation and atheroma of the aorta. Transesophageal echocardiography (TEE) is superior in identifying potential cardiac sources of emboli. Due to insufficient data on TEE findings in ischemic stroke in Iran, the present study was done to evaluate TEE in...
متن کاملThallium 201 Imaging and Gated Cardiac Blood Pool Scans in Patients with Ischemic and Idiopathic Congestive Cardiomyopathy
In ischemic cardiomyopathy (CM) fibrosis replaces large segments of myocardium, but in idiopathic congestive CM the myocardium contains only small foci of fibrosis or is morphologically normal. As coronary disease and myocardial infarction may be clinically silent, it is not always possible to distinguish ischemic from idiopathic congestive CM during life without cardiac catheterization. To det...
متن کاملSurgical Treatment for Severe Heart Failure: Recent Progress in Treatment Strategy and its Present Status in Japan
Chronic intractable heart failure that is unresponsive to maximum medical therapy can have a wide variety of causes; these include advanced valvular diseases and severe myocardial ischemia, ischemic cardiomyopathy (ICM) in heart failure following extensive myocardial infarction, chronic heart failure due to dilated cardiomyopathy (DCM) in which the myocardium itself is progressively damaged or ...
متن کاملEvaluation of Cardiac Mitochondrial Function by a Nuclear Imaging Technique using Technetium-99m-MIBI Uptake Kinetics
Mitochondria play an important role in energy production for the cell. The proper function of a myocardial cell largely depends on the functional capacity of the mitochondria. Therefore it is necessary to establish a novel and reliable method for a non-invasive assessment of mitochondrial function and metabolism in humans. Although originally designed for evaluating myocardial perfusion, 99mTc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 88 2 شماره
صفحات -
تاریخ انتشار 1993