Efficacy of pacing therapies for treating atrial tachyarrhythmias in patients with ventricular arrhythmias receiving a dual-chamber implantable cardioverter defibrillator.
نویسندگان
چکیده
BACKGROUND Although overdrive pacing for treating atrial flutter is well established, the efficacy of device-based atrial pacing for treating spontaneous atrial tachyarrhythmias in patients with implantable cardioverter defibrillators (ICD) is unknown. This study evaluated the efficacy of novel pacing therapies for treating atrial tachyarrhythmias in patients receiving a dual-chamber ICD to treat ventricular tachyarrhythmias. METHODS AND RESULTS A Jewel AF ICD was implanted in 537 patients with ventricular arrhythmia who were followed for 11.4+/-8.2 months (74% had a documented history of atrial tachyarrhythmias). The device discriminated atrial tachycardia (AT) from atrial fibrillation (AF) on the basis of cycle length and regularity, and it used 3 different methods of overdrive atrial pacing (Ramp, Burst+, and 50-Hz burst) to treat AT episodes and one method (50-Hz burst) to treat AF episodes. Pacing successfully terminated 59% of 1500 spontaneous AT episodes in 127 patients and 30% of 880 AF episodes in 101 patients (P<0.001). With AT and AF episodes combined, pacing efficacy was 48%. Pacing efficacy was significantly reduced at AT cycle lengths </=220 ms and AF cycle lengths </=160 ms (P<0.01) The median time from pacing to AT/AF termination was 1.1 minute for the pacing successes and 96 minutes for the failures (P<0.001). CONCLUSIONS Atrial pacing terminated 48% of AT/AF episodes in patients with a history of ventricular arrhythmias. Pacing efficacy was greater for device-classified AT than AF. Pacing efficacy was significantly influenced by tachycardia cycle length. Successful pacing significantly reduces the time required for AT/AF termination.
منابع مشابه
The implantable cardioverter defibrillator.
Implantable cardioverter defibrillators (ICDs) have evolved from the treatment of last resort to the gold standard therapy for patients at high risk for ventricular tachyarrhythmias. High-risk patients include those who have survived life-threatening arrhythmias, and individuals with cardiac diseases who are at risk for such arrhythmias, but are symptomless. Use of an ICD will affect the patien...
متن کاملImplantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملEfficacy of a dual chamber defibrillator with atrial antitachycardia functions in treating spontaneous atrial tachyarrhythmias in patients with life-threatening ventricular tachyarrhythmias.
BACKGROUND Atrial fibrillation has a high incidence in patients wearing an implantable cardioverter defibrillator for ventricular tachyarrhythmias and may lead to palpitations, heart failure, angina, stroke and inappropriate defibrillator discharge. The aim of the study was to evaluate the efficacy of a dual chamber defibrillator with atrial antitachycardia functions in treating spontaneous atr...
متن کاملTrouble Shooting of ICD Therapy: Inappropriate Shock
Patients with an implantable cardioverter defibrillator (ICD) can undergo inappropriate therapies (shock or antitachycardia pacing) if electrical activity not originating in the ventricle is wrongly recognized as ventricular by the device. Inappropriate therapy leading to shocks is not innocuous; consequences include pain and its psychological sequelae, particularly anxiety, as well as inductio...
متن کاملThe DATAS rationale and design: a controlled, randomized trial to assess the clinical benefit of dual chamber (DDED) defibrillator.
Single chamber (SC) implantable cardioverter defibrillators (ICDs) have several limitations that might be relevant during follow-up, like atrial pacing requirements, inadequate therapies, sustained atrial tachyarrhythmias and difficulties to achieve an accurate diagnosis of the arrhythmia. Dual chamber (DC) ICDs offer an attractive and rational solution, although controversy remains if the cost...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 104 8 شماره
صفحات -
تاریخ انتشار 2001