Gadopentetate dimeglumine as a contrast agent in common carotid arteriography.

نویسندگان

  • W K Erly
  • J Zaetta
  • G T Borders
  • H Ozgur
  • D R Gabaeff
  • R F Carmody
  • J Seeger
چکیده

BACKGROUND AND PURPOSE Despite improvements in noninvasive imaging, some patients with contraindications to iodine-based contrast material still require angiography for the evaluation of carotid stenosis. Our aim was to assess the utility of gadopentetate dimeglumine as an intraarterial contrast agent in common carotid angiography. METHODS Twelve patients with suspected carotid artery stenosis were enrolled in the study. In addition to the standard injection sequences with iohexol, common carotid arteriograms were obtained after administration of gadopentetate dimeglumine. Neurologic status and vital signs were monitored during and for 6 hours after the examination. For each injection, five independent observers, blinded to the contrast agent used, measured the percentage of carotid stenosis and assessed their confidence in grading the stenosis, the overall quality of the examination, and, in cases of decreased quality, the reason(s) for it. Statistical analysis was done with paired and unpaired t-tests with equal variances. RESULTS No patient had an adverse clinical outcome, and measurements of carotid artery stenosis showed no statistically significant differences between the gadopentetate dimeglumine and iohexol examinations. Overall image quality and observer confidence in measurements of stenosis on the gadolinium-based studies were slightly but significantly lower than those of identical iodine-based studies. CONCLUSION Gadopentetate dimeglumine may be an alternative to iodine in selected patients undergoing carotid angiography. Although overall image quality of the gadolinium studies is slightly inferior to that of the iohexol studies, measurements of carotid artery stenosis are similar for the two examinations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gadolinium as an alternative contrast agent for diagnostic and interventional angiographic procedures in patients with impaired renal function.

BACKGROUND The study was designed to investigate the safety and feasibility of gadopentetate dimeglumine, a gadolinium-based contrast medium, as an alternative angiographic contrast agent in patients with impaired renal function and high risk for iodinated contrast-induced nephropathy. METHODS Gadopentetate dimeglumine was used as the radiographic contrast agent in 32 diagnostic or interventi...

متن کامل

Comparison of gadobenate dimeglumine and gadopentetate dimeglumine: a study of MR imaging and inductively coupled plasma atomic emission spectroscopy in rat brain tumors.

BACKGROUND AND PURPOSE After the advent of extracellular contrast media, hepatobiliary-specific gadolinium chelates were developed to improve the diagnostic value of MR imaging of the liver. Gadobenate dimeglumine (Gd-BOPTA) is a new paramagnetic contrast agent with partial biliary excretion that produces prolonged enhancement of liver parenchyma on T1-weighted images. However, whether Gd-BOPTA...

متن کامل

Molecular MRI of intracranial thrombus in a rat ischemic stroke model.

BACKGROUND AND PURPOSE Intracranial thrombus is a principal feature in most ischemic stroke, and thrombus location and size may correlate with outcome and response to thrombolytic therapy. EP-2104R is a fibrin-specific molecular MR agent that has previously been shown to enhance extracranial and venous sinus thrombi in animal models and, recently, in clinical trials. In this study, we examined ...

متن کامل

Generalized seizure after i.v. administration of gadopentetate dimeglumine.

Since its approval by the Food and Drug Administration , the use of gadopentetate dimeglumine (Magnevist; Berlex Laboratories, Wayne, NJ) for contrast-enhanced MR imaging has increased rapidly. To date, few reports of adverse anaphylactoid reactions related to use of this agent have been published (1 , 2] . Following is a report of a case of generalized seizure after IV administration of gadope...

متن کامل

Validation of early myocardial gadolinium enhancement (EGE) evaluation with "Lake Louise consensus" criteria in patients with suspected myocarditis using a single bolus of 0.1 mmol/Kg of a high relaxivity gadolinium-based contrast agent

Background Early gadolinium enhancement (EGE) has been indicated as major CMR criterion for the diagnosis of myocarditis according to the Lake Louise consensus (LLC). However, the suggested threshold of 4.0 for Early enhancement ratio (EER) specifically refers to use of conventional Gd-chelates (gadopentetate dimeglumine). Our purpose was to evaluate performance of a high relaxivity contrast ag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 21 5  شماره 

صفحات  -

تاریخ انتشار 2000