Method development and validation of HPLC tandem/mass spectrometry for quantification of perindopril arginine and amlodipine besylate combination in bulk and pharmaceutical formulations
نویسندگان
چکیده
A well-characterized and fully validated ultra-high performance liquid chromatography-electrospray ionization-tandem mass spectrometric (UHPLC-ESI-MS/MS) method was developed to reliably analyze combination of perindopril arginine and amlodipine besylate in bulk and tablet formulations. The chromatographic separation was achieved on a Waters ACQUITY UPLC® BEH C18 column with 1.7 μm particle packing which enabled the higher peak capacity, greater resolution, increased sensitivity, and higher speed of analysis using a volatile mobile phase ideally being at least 2 pH units below and above the perindopril arginine and amlodipine besylate pKa, respectively. Mass spectrometric detection was performed using electrospray ion source in positive ion polarity to profile the abundances of perindopril arginine and amlodipine besylate, using the transitions m/z 369 → m/z 172, and m/z 409 → m/z 238 for perindopril arginine and amlodipine besylate, respectively. Calibration curve was constructed over the range 0.25 - 500 ng/mL and 1.0 - 100 ng/mL for perindopril arginine and amlodipine besylate, respectively. The method was precise and accurate, and provided recovery rates > 80% for both compounds. Furthermore, the intra- and inter-assay precision in terms of % RSD was in between 0.1 - 3.7 for both perindopril arginine and amlodipine besylate. A specific, accurate, and precise UHPLC-MS/MS method for the determination of perindopril arginine and amlodipine besylate in bulk and tablet formulation.
منابع مشابه
Simultaneous estimation of amlodipine besylate and nebivolol hydrochloride in pharmaceutical tablets formulation by RP-HPLC using PDA detector
Background: The present work was undertaken with the aim to develop and validate a rapid and consistent RP-HPLC method in which the peaks will be appear with short period of time as per ICH Guidelines. Materials and Methods: The separation was achieved on a a stainless steel analytical column, Eclipse XDB plus C18 column (4.6 X 150 mm; 5 μm) in an isocratic mode. The mobile phase w...
متن کاملA Quick and Sensitive Liquid Chromatography-Tandem Mass Spectrometry (LC-MS) Method for the Evaluation of Two Formulations of Amlodipine and Atorvastatin in Healthy Male Volunteers
An open-label, single-dose, randomized, 2-way crossover study was conducted in fasted healthy Iranian male volunteers. Eligible participants randomly assigned in a 1:1 ratio to be given one tablet of the test or reference formulation, followed by a 2-week washout period and administration of the exchange formulation. A quick and susceptible Liquid Chromatography–tandem Mass Spectro...
متن کاملAmlodipine besylate-excipients interaction in solid dosage form.
This article studies the compatibility of amlodipine besylate in its solid formulations with various drug excipients. The various factors affecting amlodipine besylate stability were studied using high-performance liquid chromatography (HPLC). It has been found that binary 1:1 mixtures of amlodipine besylate and an excipient are stable at 65 degrees C and 40 degrees C/75% RH. Further investigat...
متن کاملValidated Chromatographic Methods for Simultaneous Determination of Amlodipine Besylate and Perindopril Arginine in Binary Mixtures and in Pharmaceutical Dosage Form
The developed RP-HPLC depends on quantitative chromatographic separation of the studied drugs on a C18 column using phosphate Buffer:acetonitrile (60:40, v/v), pH=4.6 as a mobile phase delivered at constant flow rate of 1 mL.min-1 with UV detection at 210 nm. Calibration curves for Amlodipine besylate and Perindopril Arginine were constructed over the concentration range of 1-50 μg.mL-1 for bot...
متن کاملDevelopment and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry
The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...
متن کامل