Cochlear blood flow increases after systemic hemodilution: comparison of simultaneous laser Doppler flowmetry and radioactive microsphere measurements.
نویسندگان
چکیده
Guinea pig cochlear blood flow was measured before and after systemic normovolemic hemodilution with high molecular weight dextran. Absolute determinations of blood flow (in the cochlea, brain, kidney and lung) were accomplished by use of radioactive-labeled (85Sr or 141Ce) microspheres. Relative measurements of the cochlear blood flow changes were made simultaneously by the use of a laser Doppler flowmeter. The flowmeter probe was placed on the first cochlear turn. Hemodilution to an average systemic hematocrit of 20% increased cochlear blood flow by 250% as measured with microspheres. The laser Doppler instrument significantly underestimated the actual flow increase giving an indication of 148%. Furthermore, the data, when analyzed on an individual trial basis, showed a very poor correlation between the two methods. The theoretical basis for these findings in relation to the use of the laser Doppler instrument is discussed.
منابع مشابه
Evaluation of Carpal Tunnel Syndrome by Laser Doppler Flowmetry
Background:Autonomic disturbance can leads to blood flow changes that can be studied by various methods. Objective: To assess the blood flow changes in patients with severe carpal tunnel syndrome by laser Doppler flowmetry Methods:Ten patients with severe unilateral carpal tunnel syndrome confirmed by electrodiagnostic examination enrolled in this study. Patients comprised one man and nine wom...
متن کاملChanges in cochlear blood flow in mice due to loud sound exposure measured with Doppler optical microangiography and laser Doppler flowmetry.
In this work we determined the contributions of loud sound exposure (LSE) on cochlear blood flow (CoBF) in an in vivo anesthetized mouse model. A broadband noise system (20 kHz bandwidth) with an intensity of 119 dB SPL, was used for a period of one hour to produce a loud sound stimulus. Two techniques were used to study the changes in blood flow, a Doppler optical microangiography (DOMAG) syst...
متن کاملEffects of hypoxia on cochlear blood flow in mice evaluated using Doppler optical microangiography.
Reduced cochlear blood flow (CoBF) is a main contributor to hearing loss. Studying CoBF has remained a challenge due to the lack of available tools. Doppler optical microangiography (DOMAG), a method to quantify single-vessel absolute blood flow, and laser Doppler flowmetry (LDF), a method for measuring the relative blood flow within a large volume of tissue, were used for determining the chang...
متن کاملDepth of penetration of scanning laser Doppler flowmetry in the primate optic nerve.
OBJECTIVES To estimate the measuring depth of the blood flow and to establish the vascular contributions to these measurements with scanning laser Doppler flowmetry (SLDF) of the primate anterior optic nerve. METHODS Optic nerve blood flow in each eye of 8 monkeys was measured using SLDF before and following surgical occlusion of the central retinal artery (n = 4) or posterior ciliary arterie...
متن کاملEffects of vasodilating agents on cochlear blood flow in mice.
The mouse has several distinct advantages as an experimental model for study of the cochlear blood flow (CBF) in the mammal, particularly for studies involving genetic manipulation, development and aging factors. In this investigation we evaluated the effects of selected vasodilating agents on CBF using laser-Doppler flowmetry. Sodium nitroprusside, hydralazine and pentoxifylline were applied t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Hearing research
دوره 34 3 شماره
صفحات -
تاریخ انتشار 1988