The detection of impending failure in implanted pacemakers.

نویسندگان

  • J G Davies
  • H Siddons
چکیده

As implantable pacemakers last a variable time, it is desirable to be able to foretell when each individual pacemaker is nearing the end of its life. A test which detects a number of different impending electronic failures including battery depletion is described. The test requires only standard laboratory equipment and has been used for four years as a three-monthly procedure in an out-patient clinic. In 17 of 19 consecutive patients the test has enabled a change of pacemaker to be carried out electively, rather than after an arbitrary period or as an emergency when pacing has failed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of battery depletion in implanted pacemakers.

By the use of a measuring oscilloscope and the standard electrocardiogram limb leads the degree of battery depletion in an implanted pacemaker can be estimated. A formula based on readings obtained by this means has been used to determine when Devices fixed rate pacemakers should be removed. Laboratory tests show that 90% of their useful life is obtained by this means and it proved possible to ...

متن کامل

Clinical testing of implanted pacemakers.

The function of implanted pacemakers was assessed at a special pacemaker clinic at intervals of three to six months. Measurements of the basic discharge rate of the pacemaker were made and the waveform was recovered from skin electrodes and displayed on an oscilloscope screen. The impulse was photographed from the screen and subsequent waveform analysis was carried out. Reproducible results wer...

متن کامل

Experience with Devices implanted fixed-rate pacemakers.

The fate of 183 implants of Devices TF 2970 fixed-rate pacemakers is analysed. The incidence of clinical complications such as sepsis or skin necrosis, displacement of the electrode, and exit block, and the causes of the 19 deaths are discussed. In 28 of the 183 pacemakers pacing stopped for technical reasons, which are described; the commonest cause of failure was the batteries. The incidence ...

متن کامل

Experience with Implanted Pacemakers: Technical Considerations.

Between April 1960 and September 1964, 79 patients were treated with implanted pacemakers. We record here the technical difficulties encountered and the steps taken to overcome them. In all cases the indication for artificial pacing was failure of medical treatment to prevent Stokes-Adams attacks or to relieve cardiac failure due to a slow pulse. Most, but not all, patients were in complete hea...

متن کامل

A clinical appraisal

A technique for determining the characteristics of impulses from implanted cardiac pacemakers with external methods is reviewed, and its value in detecting pacemaker failures is discussed. The resultsfrom a 2-year application with 6ii controls in clinical routine are presented. Sixteen out of b*42 defective pacemakers could be detected before symptoms or electrocardiographic signs of pacing fai...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 24 1  شماره 

صفحات  -

تاریخ انتشار 1969