A biomechanical study of conventional acetabular internal fracture fixation versus locking plate fixation.

نویسندگان

  • Ramin Mehin
  • Bryn Jones
  • Qingan Zhu
  • Henry Broekhuyse
چکیده

BACKGROUND Conventional internal fixation entails the use of an interfragmentary lag screw along with a plate. Not all acetabular fractures are amenable to the placement of an interfragmentary lag screw, and the fracture may be displaced during tightening of the interfragmentary lag screw. Locking plates are a possible solution. We sought to determine whether a locking plate construct can provide stability equivalent to that provided with a conventional construct for transverse acetabular fractures. METHODS We used 5 paired fresh-frozen cadaveric acetabula. We fixed one side with the conventional technique and the other side with a locking plate. We subjected each fixation to a cyclic compressive force up to 500 cycles, followed by compressive force until failure. We monitored 3-dimensional motion of the fracture. RESULTS The average fracture gap at 50 N compressive force after 500 loading cycles was 0.41 (standard deviation [SD] 0.49) mm for the conventional plate and lag screw construct compared with 0.76 (SD 0.62) mm for the locked plate construct (p = 0.46). The force to failure, as defined by 2 mm of fracture gap, was 848 (SD 805) N for the conventional plate and lag screw construct compared with 506 (SD 277) N for the locked plate fixation (p = 0.34). CONCLUSION The locking plate construct is as strong as the conventional plate plus interfragmentary lag screw construct for fixing transverse acetabular fractures. Locking plates may improve management of acetabular fractures by eliminating the need for placement of an interfragmentary lag screw. Furthermore, they may be helpful in revision hip arthroplasty in patients with pelvic discontinuity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single column locking plate fixation is inadequate in two column acetabular fractures. A biomechanical analysis

BACKGROUND The objective of this study was to determine whether one can achieve stable fixation of a two column (transverse) acetabular fracture by only fixing a single column with a locking plate and unicortical locking screws. We hypothesized that a locking plate applied to the anterior column of a transverse acetabular fracture would create a construct that is more rigid than a non-locking p...

متن کامل

Biomechanical Comparison of Different Stabilization Constructs for Unstable Posterior Wall Fractures of Acetabulum. A Cadaveric Study

PURPOSE Operative treatment of unstable posterior wall fractures of acetabulum has been widely recommended. This laboratory study was undertaken to evaluate static fixation strength of three common fixation constructs: interfragmentary screws alone, in combination with conventional reconstruction plate, or locking reconstruction plate. METHODS Six formalin-preserved cadaveric pelvises were us...

متن کامل

A Novel Fixation System for Acetabular Quadrilateral Plate Fracture: A Comparative Biomechanical Study

This study aims to assess the biomechanical properties of a novel fixation system (named AFRIF) and to compare it with other five different fixation techniques for quadrilateral plate fractures. This in vitro biomechanical experiment has shown that the multidirectional titanium fixation (MTF) and pelvic brim long screws fixation (PBSF) provided the strongest fixation for quadrilateral plate fra...

متن کامل

Biomechanical In Vitro - Stability Testing on Human Specimens of a Locking Plate System Against Conventional Screw Fixation of a Proximal First Metatarsal Lateral Displacement Osteotomy

INTRODUCTION The aim of this study was to examine resistance to angulation and displacement of the internal fixation of a proximal first metatarsal lateral displacement osteotomy, using a locking plate system compared with a conventional crossed screw fixation. MATERIALS AND METHODOLOGY Seven anatomical human specimens were tested. Each specimen was tested with a locking screw plate as well a...

متن کامل

A contoured locking plate: Biomechanical evaluation of an osteosynthesis for osteoporotic ankle fractures

Introduction Ankle fractures involving the distal fibula belong to the most common fractures. Operative treatment is indicated in unstable ankle fractures by open reduction and internal fixation with plate and screws. Especially in the elderly, the osteoporotic bone provides reduced stabilization of this fixation. Therefore, an implant providing improved mechanical stabilization could allow a m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Canadian journal of surgery. Journal canadien de chirurgie

دوره 52 3  شماره 

صفحات  -

تاریخ انتشار 2009