In vivo flow dynamics of the total cavopulmonary connection from three-dimensional multislice magnetic resonance imaging.

نویسندگان

  • S Sharma
  • A E Ensley
  • K Hopkins
  • G P Chatzimavroudis
  • T M Healy
  • V K Tam
  • K R Kanter
  • A P Yoganathan
چکیده

BACKGROUND The total cavopulmonary connection (TCPC) design continues to be refined on the basis of flow analysis at the connection site. These refinements are of importance for myocardial energy conservation in the univentricular supported circulation. In vivo magnetic resonance phase contrast imaging provides semiquantitative flow visualization information. The purpose of this study was to understand the in vivo TCPC flow characteristics obtained by magnetic resonance phase contrast imaging and compare the results with our previous in vitro TCPC flow experiments in an effort to further refine TCPC surgical design. METHODS Twelve patients with TCPC underwent sedated three-dimensional, multislice magnetic resonance phase contrast imaging. Seven patients had intraatrial lateral tunnel TCPC and 5 had extracardiac TCPC. RESULTS In all patients in both groups a disordered flow pattern was observed in the inferior caval portion of the TCPC. Flow at the TCPC site appeared to be determined by connection geometry, being streamlined at the superior vena cava-pulmonary junction when the superior vena cava was offset and flared toward the left pulmonary artery. Without caval offset, intense swirling and dominance of superior vena caval flow was observed. In TCPC with bilateral superior vena cavae, the flow patterns observed included secondary vortices, a central stagnation point, and influx of the superior vena cava flow into the inferior caval conduit. A comparative analysis of in vivo flow and our previous in vitro flow data from glass model prototypes of TCPC demonstrated significant similarities in flow disturbances. Three-dimensional magnetic resonance phase contrast imaging in multiple coronal planes enabled a comprehensive semiquantitative flow analysis. The data are presented in traditional instantaneous images and in animated format for interactive display of the flow dynamics. CONCLUSIONS Flow in the inferior caval portion of the TCPC is disordered, and the TCPC geometry determines flow characteristics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic resonance imaging of feline eye

The purpose of this study was to investigate magnetic resonance imaging (MRI) of the normal feline eyeand optic nerves using T1-weighted and T2-weighted images. A total of 6 healthy female domestic short haircats age 2-2.5 years and weighing 3.2 ± 0.4 kg were selected. Magnetic resonance imaging data werecollected using GEMSOW (Philips) at a magnetic field strength of 1.5 T. Dorsal, sagittal, a...

متن کامل

Images in cardiovascular medicine. In vivo 3-dimensional flow connectivity mapping after extracardiac total cavopulmonary connection.

We present findings in an 18-year-old female patient with a double-inlet single ventricle 12 years after extracardic total cavopulmonary connection (TCPC)1 who also presented with a Waldhausen repair of aortic coarctation. To evaluate arterial and venous anatomy and to assess time-resolved 3-dimensional (3D) blood flow in the venous and pulmonary system, flow-sensitive 4-dimensional magnetic re...

متن کامل

Noninvasive quantification of fluid mechanical energy losses in the total cavopulmonary connection with magnetic resonance phase velocity mapping.

A major determinant of the success of surgical vascular modifications, such as the total cavopulmonary connection (TCPC), is the energetic efficiency that is assessed by calculating the mechanical energy loss of blood flow through the new connection. Currently, however, to determine the energy loss, invasive pressure measurements are necessary. Therefore, this study evaluated the feasibility of...

متن کامل

Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System

  Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...

متن کامل

The beneficial vortex and best spatial arrangement in total extracardiac cavopulmonary connection.

OBJECTIVE Total extracardiac cavopulmonary connection is an established procedure, but the best spatial arrangement remains controversial. On the basis of our clinical experience with total extracardiac cavopulmonary connection, we performed quantitative and qualitative flow analysis on total extracardiac cavopulmonary connection models simulating the two most frequent arrangements applied to o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of thoracic surgery

دوره 71 3  شماره 

صفحات  -

تاریخ انتشار 2001