Parametric analysis using the finite element method to investigate prosthetic interface stresses for persons with trans-tibial amputation.
نویسندگان
چکیده
A finite element (FE) model of the below-knee residual limb and prosthetic socket was created to investigate the effects of parameter variations on the interface stress distribution during static stance. This model was based upon geometric approximations of anthropometric residual limb geometry. The model was not specific to an individual with amputation, but could be scaled to approximate the limb of a particular subject. Parametric analyses were conducted to investigate the effects of prosthetic socket design and residual limb geometry on the residual limb/prosthetic socket interface stresses. Behavioral trends were illustrated via sensitivity analysis. The results of the parametric analyses indicate that the residual limb/prosthetic socket interface stresses are affected by variations in both prosthetic design and residual limb geometry. Specifically, the analyses indicate: 1) the residual limb/prosthetic liner interface pressures are relatively insensitive to the socket stiffness; 2) the stiffness of the prosthetic liner influences the interface stress distribution for both the unrectified and patellar-tendon-bearing (PTB) rectified models-the external load state appears to influence the interface pressure distribution, while the prosthetic socket rectification appears to influence the interface shear stress distribution; 3) the interface pressures are very sensitive to the prosthetic rectification; 4) the shape and relative bulk of soft tissue may significantly influence the interface pressure distribution; 5) the interface pressure distribution is also influenced by the residual limb length; and 6) the stiffness/compliance of the residual limb soft tissues may significantly alter the interface pressure distribution.
منابع مشابه
Parametric analysis using the finite element method to investigate prosthetic interface stresses for persons with below-knee amputation
A finite element (FE) model of the below-knee residual limb and prosthetic socket was created to investigate the effects of parameter variations on the interface stress distribution during static stance . This model was based upon geometric approximations of anthropometric residual limb geometry . The model was not specific to an individual with amputation, but could be scaled to approximate th...
متن کاملOn the Displacement-Stress Continuous Finite Elements
For the analysis of composite media, three different compatible and mixed finite element formulations are presented which apriori enforce the continuity of stresses as well as displacements at the element interfaces. The formulations are applied for the analysis of hi-material interfaces in two problems often encountered in the field of orthopaedic biomechanics, that is the fixation analysis in...
متن کاملStress analysis of all-ceramic three-unit dental bridges using finite element method
Stress analysis of all-ceramic three-unit dental bridges using finite element method M.F. Biria *- Dr. F. Farahmand** - Dr. Gh. Eslami Amirabadi*** *- M.S in Biomechanics Engineering Faculty of Mechanics. Sharif Industrial University. ** - Associate professor of Mecanical Engineering Dept. Sharif Industrial University. *** - Assistant professor of Orthodontics Dept. Faculty of Dentistry Shahed...
متن کاملGeneric, geometric finite element analysis of the transtibial residual limb and prosthetic socket.
Finite element (FE) analysis was used to investigate the stress distribution between the residual limb and prosthetic socket of persons with transtibial amputation (TTA). The purpose of this study was to develop a tool to provide a quantitative estimate of prosthetic interface pressures to improve our understanding of residual limb/prosthetic socket biomechanics and prosthetic fit. FE models of...
متن کاملInternal mechanical conditions in the soft tissues of a residual limb of a trans-tibial amputee.
Most trans-tibial amputation (TTA) patients use a prosthesis to retain upright mobility capabilities. Unfortunately, interaction between the residual limb and the prosthetic socket causes elevated internal strains and stresses in the muscle and fat tissues in the residual limb, which may lead to deep tissue injury (DTI) and other complications. Presently, there is paucity of information on the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of rehabilitation research and development
دوره 33 3 شماره
صفحات -
تاریخ انتشار 1996