In vivo confocal microscopy of pre-Descemet corneal dystrophy associated with X-linked ichthyosis: a case report
نویسندگان
چکیده
BACKGROUND Pre-Descemet corneal dystrophy (PDCD) is characterized by the presence of numerous, tiny, polymorphic opacities immediately anterior to Descemet membrane, which is a rare form of corneal stromal dystrophy and hard to be diagnosed. In vivo confocal microscopy (IVCM) is a useful tool to examine the minimal lesions of the cornea at the cellular level. In this article, we report a rare case of PDCD associated with X-linked ichthyosis and evaluate IVCM findings. CASE PRESENTATION We present a 34-year-old male Chinese patient with PDCD associated with X-linked ichthyosis. Slit-lamp biomicroscopy showed the presence of tiny and pleomorphic opacities in the posterior stroma immediately anterior to Descemet membrane bilaterally. IVCM revealed regular distributed hyperreflective particles inside the enlarged and activated keratocytes in the posterior stroma. Hyperreflective particles were also observed dispersedly outside the keratocytes in the anterior stroma. Dermatological examination revealed that the skin over the patient's entire body was dry and coarse, with thickening and scaling of the skin in the extensor side of the extremities. PCR results demonstrated that all ten exons and part flanking sequences of STS gene failed to produce any amplicons in the patient. CONCLUSIONS IVCM is useful for analyzing the living corneal structural changes in rare corneal dystrophies. We first reported the IVCM characteristics of PDCD associated with X-linked ichthyosis, which was caused by a deletion of the steroid sulfatase (STS) gene, confirmed by gene analysis.
منابع مشابه
Variations of the Normal Human Limbal Stem Cells Detected by In Vivo Confocal Microscopy
Background To report normal variations of the limbal structures using in vivo laser scanning confocal microscopy. Methods: This was a retrospective study of fourteen eyes from 11 healthy individuals. Confocal imaging of cornea and limbus was performed using Heidelberg Retina Tomograph III Rostock Corneal Module. Results: The typical structure of the palisades of Vogt (POV) was detected ...
متن کاملDescemet stripping automated endothelial keratoplasty in Fuchs’ corneal endothelial dystrophy: anterior segment optical coherence tomography and in vivo confocal microscopy analysis
BACKGROUND To evaluate the in vivo corneal changes using in vivo confocal microscopy (IVCM) and anterior segment optical coherence tomography (AS-OCT) in patients with Fuchs' dystrophy who underwent Descemet stripping automated endothelial keratoplasty (DSAEK) and the relationship between these changes and the postoperative visual recovery up to 1-year follow-up. METHODS Before DSAEK and 1 da...
متن کاملPosterior Corneal Steepening in Posterior Polymorphous Corneal Dystrophy.
PURPOSE The aim was to evaluate the anterior and posterior corneal topographic characteristics of three patients with posterior polymorphous corneal dystrophy (PPCD) using a rotating Scheimpflug camera combined with a Placido disc system (Sirius, CSO, Italy). CASE REPORTS Two children with unilateral PPCD and a 53-year-old woman with bilateral PPCD were diagnosed by the presence of vesicles a...
متن کاملIn vivo confocal microscopy in different types of posterior polymorphous dystrophy
Posterior polymorphous dystrophy is a rare corneal dystrophy, usually detected by chance. This case series describes the morphologic features in the three different types of posterior polymorphous dystrophy using confocal microscopy.
متن کاملFirst Identification of a Triple Corneal Dystrophy Association: Keratoconus, Epithelial Basement Membrane Corneal Dystrophy and Fuchs’ Endothelial Corneal Dystrophy
PURPOSE To report the observation of a triple corneal dystrophy association consisting of keratoconus (KC), epithelial basement membrane corneal dystrophy (EBMCD) and Fuchs' endothelial corneal dystrophy (FECD). METHODS A 55-year-old male patient was referred to our cornea service for blurred vision and recurrent foreign body sensation. He reported bilateral recurrent corneal erosions with di...
متن کامل