Technical Analysis of cDNA Microarrays

نویسندگان

  • Cinda P. Scott
  • Jeff VanWye
  • M. Danielle McDonald
  • Douglas L. Crawford
چکیده

BACKGROUND There is extensive variation in gene expression among individuals within and between populations. Accurate measures of the variation in mRNA expression using microarrays can be confounded by technical variation, which includes variation in RNA isolation procedures, day of hybridization and methods used to amplify and dye label RNA for hybridization. METHODOLOGY/PRINCIPAL FINDINGS In this manuscript we analyze the relationship between the amount of mRNA and the fluorescent signal from the microarray hybridizations demonstrating that for a wide-range of mRNA concentrations the fluorescent signal is a linear function of the amount of mRNA. Additionally, the separate isolation, labeling or hybridization of RNA does not add significant amounts of variation in microarray measures of gene expression. However, single or double rounds of amplification for labeling do have small but significant affects on 10% of genes, but this source of technical variation is easy to avoid. To examine both technical and stochastic biological variation, mRNA expression was measured from the same five individuals over a six-week time course. CONCLUSION There were few, if any, meaningful differences in gene expression among time points. Thus, microarray measures using standard laboratory procedures can be precise and quantitative and are not subject to significant random biological noise.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dye bias correction in dual-labeled cDNA microarray gene expression measurements.

A significant limitation to the analytical accuracy and precision of dual-labeled spotted cDNA microarrays is the signal error due to dye bias. Transcript-dependent dye bias may be due to gene-specific differences of incorporation of two distinctly different chemical dyes and the resultant differential hybridization efficiencies of these two chemically different targets for the same probe. Seve...

متن کامل

Evidence of cross-hybridization artifact in expressed sequence tags (ESTs) on cDNA microarrays

We present evidence of cross-hybridization artifact intrinsic to spotted single-dye cDNA microarrays as a result of cDNA containing 5’-end sequences of consecutive thymidine (dT) residues. These poly(dT) tracts result from the synthesis, via oligo (dT) primed reverse transcription, of expressed sequence tags (EST) cDNA from a polyadenylated mRNA template. Analysis of gene expression data from t...

متن کامل

Systematic-Methodological Platforms RNA SMP: RNA Project: Analysis of Murine Tumor Models and Human Tumors

Introduction Today, researchers can choose from a broad variety of methods for global transcriptional profiling. Among the different technical approaches, microarray technology has gained a premier position. In principle, microarrays can be produced either by robotic printing (“spotting”) of DNA on a chemically modified glass surface1, or by in situ synthesis of oligonucleotides on a silane-rea...

متن کامل

Use of laser capture microdissection, cDNA microarrays, and tissue microarrays in advancing our understanding of prostate cancer.

One difficulty in studying epithelial tumors has been the inability to isolate pure samples for DNA and RNA analysis. Prostate cancer, with its infiltrative nature, is particularly challenging. The Combination of several new technologies should help overcome these hurdles. Laser capture microdissection uses a laser beam to achieve transfer of pure cell populations for isolation of DNA, RNA, and...

متن کامل

Combining signals from spotted cDNA microarrays obtained at different scanning intensities

MOTIVATION The analysis of spotted cDNA microarrays involves scanning of color signals from fluorescent dyes. A common problem is that a given scanning intensity is not usually optimal for all spotted cDNAs. Specifically, some spots may be at the saturation limit, resulting in poor separation of signals from different tissues or conditions. The problem may be addressed by multiple scans with va...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • PLoS ONE

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2009