Simulating Ventricular Septal Defect
نویسندگان
چکیده
The classic findings of a patent ductus arteriosus in a young individual are familiar to most physicians. However, it has been appreciated that several factors, principally pulmonary hypertension or pulmonary artery dilatation in the absence of appreciable hypertension, may significantly alter the classic image and lead to the erroneous diagnosis of ventricular septal defect. In 10 surgically proved cases a patent ductus arteriosus
منابع مشابه
Right-sided Infective Endocarditis with Multiple Large Vegetations in a Case of Ventricular Septal Defect: A Case Report
Herein, we present the case of a 10-year-old child suffering from right-sided infective endocarditis with ventricular septal defect. Echocardiography revealed multiple rare large vegetations on the pulmonary valve extending into pulmonary artery along with a large vegetation over the septal leaflet of the tricuspid valve.
متن کاملUrgent Surgical Intervention for Embolized Cardiac Occluder Devices: A Case Series
Introduction: In this study, we sought to illustrate our experience in urgent surgical management for embolized cardiac septal occlude devices resulting from trans-catheter closure of atrial septal defect and ventricular septal defect. Mathrials and Methods: We retrospectively reviewed four patients aged 2–10 years who underwent urgent surgery due to cardiac septal occluder embolization between...
متن کاملInvestigating Diverse Structure of Pulmonary Blood Vessels in Patients with Combined Pulmonary Atresia and Ventricular Septal Defect and Examining the Effect on Surgery Result
Background This study aimed to investigate diverse structure of pulmonary blood vessels in patients with combined pulmonary atresia and ventricular septal defect and examine the effect on surgery result. Materials and Methods This cohort retrospective study was conducted on admitta...
متن کاملSimulating Ventricular Septal Defect
The classic findings of a patent ductus arteriosus in a young individual are familiar to most physicians. However, it has been appreciated that several factors, principally pulmonary hypertension or pulmonary artery dilatation in the absence of appreciable hypertension, may significantly alter the classic image and lead to the erroneous diagnosis of ventricular septal defect. In 10 surgically p...
متن کاملVentricular septal defect simulating patent ductus arteriosus.
The continuous machinery murmur heard over the pulmonary area is generally evidence of a patent ductus arteriosus, but there are exceptions when the murmur is due to congenital aortic septal defect (Gross, 1952; Gasul et al., 1951), to perforated aortic sinus into the right ventricle (Jones and Langley, 1949; Wood, 1950), or to rupture of an aortic aneurysm into the pulmonary artery (White et a...