Comparison of quantitative coronary angiography, intravascular ultrasound, and coronary pressure measurement to assess optimum stent deployment.
نویسندگان
چکیده
BACKGROUND Although intravascular ultrasound (IVUS) is the present standard for the evaluation of optimum stent deployment, this technique is expensive and not routinely feasible in most catheterization laboratories. Coronary pressure-derived myocardial fractional flow reserve (FFRmyo) is an easy, cheap, and rapidly obtainable index that is specific for the conductance of the epicardial coronary artery. In this study, we investigated the usefulness of coronary pressure measurement to predict optimum and suboptimum stent deployment. METHODS AND RESULTS In 30 patients, a Wiktor-i stent was implanted at different inflation pressures, starting at 6 atm and increasing step by step to 8, 10, 12, and 14 atm, if necessary. After every step, stent deployment was evaluated by quantitative coronary angiography (QCA), IVUS, and coronary pressure measurement. If any of the 3 techniques did not yield an optimum result, the next inflation was performed, and all 3 investigational modalities were repeated until optimum stent deployment was present by all of them or until the treating physician decided to accept the result. Optimum deployment according to QCA was finally achieved in 24 patients, according to IVUS in 17 patients, and also according to coronary pressure measurement in 17 patients. During the step-up, a total of 81 paired IVUS and coronary pressure measurements were performed, of which 91% yielded concordant results (ie, either an optimum or a suboptimum expansion of the stent by both techniques, P<0.00001). On the contrary, QCA showed a low concordance rate with IVUS and FFRmyo (48% and 46%, respectively). CONCLUSIONS In this study, using a coil stent, both IVUS and coronary pressure measurement were of similar value with respect to the assessment of optimum stent deployment. Therefore, coronary pressure measurement can be used as a cheap and rapid alternative to IVUS for that purpose.
منابع مشابه
Final results of the Can Routine Ultrasound Influence Stent Expansion (CRUISE) study.
BACKGROUND Intravascular ultrasound (IVUS) can assess stent geometry more accurately than angiography. Several studies have demonstrated that the degree of stent expansion as measured by IVUS directly correlated to clinical outcome. However, it is unclear if routine ultrasound guidance of stent implantation improves clinical outcome as compared with angiographic guidance alone. METHODS AND RE...
متن کاملEarly- and long-term intravascular ultrasound and angiographic findings after bioabsorbable magnesium stent implantation in human coronary arteries.
OBJECTIVES This study aimed to evaluate the degradation rate and long-term vascular responses to the absorbable metal stent (AMS). BACKGROUND The AMS demonstrated feasibility and safety at 4 months in human coronary arteries. METHODS The PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting) was a prospective, multicenter clinical trial of 63 patients with coronar...
متن کاملPercutaneous coronary revascularization using a trilayer metal phosphorylcholine-coated zotarolimus-eluting stent.
The ZoMaxx Coronary Stent System elutes the antiproliferative agent zotarolimus via a biocompatible phosphorylcholine polymer loaded onto a novel, thin, stainless steel stent platform containing an 0.0007-inch inner layer of tantalum that enhances fluoroscopic radiopacity. The objective of this single-arm prospective clinical trial was to assess the safety and performance of the ZoMaxx stent fo...
متن کاملOptimization of Stent Deployment by Intravascular Ultrasound
Intravascular ultrasound (IVUS) is a useful diagnostic method that provides valuable information in addition to angiography regarding the coronary vessel lumen, dimensions, plaque burden, and characteristics. The major use of IVUS in coronary intervention is to guide interventional strategies and assess optimal stent deployment. Since the introduction of the drug-eluting stent (DES), concerns a...
متن کاملQuantitative coronary angiographic and intravascular ultrasound assessment of a new nonarticulated stent: report from the Advanced Cardiovascular Systems MultiLink stent pilot study.
OBJECTIVES The purpose of this study was to evaluate the safety, feasibility, optimal deployment technique and 1-year clinical outcome for the Advanced Cardiovascular Systems (ACS) MultiLink stent. BACKGROUND Optimal stent deployment assessed by quantitative coronary angiography and intravascular ultrasound (IVUS) is associated with improved clinical outcome. METHODS Forty-nine consecutive ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 99 8 شماره
صفحات -
تاریخ انتشار 1999